beautypg.com

7 • installing the switch housing – Hunter Fan Type User Manual

Page 11

background image

11

45044-01 • 01/14/09 • Hunter Fan Company

7-1. To attach the upper switch housing, partially install two housing

assembly screws into the switch housing mounting plate.

7-2. Feed the upper plug connector through the center opening of the

housing.

7-3. Align the keyhole slots in the housing with the housing assembly

screws.

7-4. Turn the housing counterclockwise until the housing assembly

screws are firmly situated in the narrow end of the keyhole slots.
Install the remaining screw into the housing. Tighten all three
screws firmly.

CAUTION: Make sure the upper switch housing is securely attached

to the switch housing mounting plate. Failure to properly attach and
tighten all three assembly screws could result in the switch housing
fixture falling.

7-5. To attach the lower switch housing, connect the upper plug

connector from the motor to the lower plug connector in the
lower switch housing assembly.

Note: Both plug connectors are polarized and will only fit together

one way. Make sure the connectors are properly aligned before
connecting them. Incorrect connection could cause improper
operation and damage to the product.

7-6. Place the lower switch housing assembly over the upper switch

housing. Align the side screw holes in the upper and lower switch
housings. Attach the lower switch housing to the upper switch
housing with three housing assembly screws.

Note: You can customize your Hunter fan with a number of accessory
light kits.

Steps 7-1 – 7-4

Housing

Assembly

Screw

Upper

Switch

Housing

Housing

Assembly

Screw

Lower

Switch

Housing

Steps 7-5 – 7-6

Plug

Connector

7 • Installing the Switch Housing