UC100 ULTRAVIOLET SYSTEM REPLACEMENT BULB/HANDLE ASSEMBLY
3
69-1444—5
Fig. 4. Position lamp handle for insertion back into
the lamp base.
8. Rotate the lamp handle clockwise until it snaps into
place with the light indicator aligned with the raised
button on the unit cover. See Fig. 5.
Fig. 5. Snap lamp handle into place.
9. Reconnect power to your UV System.
10. For UV Air Treatment System SmartLamp™ models,
wait ten minutes for the airflow sensor to calibrate.
During this time, the furnace fan must remain off.
NOTE: Failure to wait ten minutes for the airflow sensor to
calibrate before powering the system fan causes the
airflow sensor to incorrectly calibrate and the device
to incorrectly function. If this occurs, remove power
to the furnace or turn off the system fan, wait ten
minutes, and then resume normal fan operation.
WARNING
UV Light Hazard.
Harmful to bare skin and eyes.
Can cause temporary or permanent loss of vision.
Never look at bulbs while illuminated.
View illumination only through light indicator located
on lamp handle.
To prevent exposure to ultraviolet light, disconnect
power to Ultraviolet System before servicing any part
of heating and air conditioning system.
11. Verify that your ultraviolet bulbs are operating by
viewing only through the lamp light indicator on the lamp
handle. Never look directly at your lamp while it is
illuminated.
12. Reconnect the power to your heating and cooling
system.
13. For SmartLamp™ models, press and hold the reset
button for five seconds to reset the internal timers.
M22847
M22849
Table 1. Replacing Your Bulb(s) and Handle Assembly.
Unit Description
Replacement Bulb/
Handle Assembly
SnapLamp™
Replacement Bulb
Wattage
UV100E1001 and UV100E1043
Air Treatment Systems
UC100E1006
UC18W
18W
UV100E1019 and UV100E2009
Air Treatment Systems (dual lamp)
UC100E1030 (2 needed)
UC36W (two bulbs required)
36W
UV100E1027 Surface Treatment System
UV100A1021
N/A
25W
UV100E1035 and UV100E3007
Surface Treatment Systems
UC100E1030
UC36W
36W
UV100A1000 Air Treatment System
UC100A1005
UC18W
18W
UV100A1018 Air Treatment System (dual lamp)
UC100A1054 (2 needed)
UC36W (two bulbs required)
36W
UV100A1026 Surface Treatment System
UC100A1021
N/A
25W
UV100A1059 Surface Treatment System
UC100A1054
UC36W
36W
UV100A2008 Surface Treatment System
UC100A1054
UC36W
36W