TECHNICAL DETAILS
Model
Cooker 60 80 100 120
Rated input kw (gross)
17.6
22.2
29.7
37.3
45.5
Rated output kw (gross)
-
17.6
23.4
29.3
35.2
Burner
Cooker
Boiler - 60k
Boiler - 80k
Boiler - 100k
Boiler - 120k
Gas Volume m 3/jr
1.68
2.11
2.84
3.56
4.34
Co2 %
8.5-9.0
7.0-8.0
8.0-8.5
8.5-9.0
8.5-9.0
Starting current - Amp
0.422
0.422
0.8
0.8
0.83
Running current - Amp
0.33
0.33
0.48
0.48
0.74
Electrical power consumption
230v 50 Hz 95 watts
Gas Type
Natural Gas 20mbar G20
Gas Cat
I
2H
for use in GB, IE (Great Britain and Eire)
Weight - dry kg
512kg
Water content - Litre
38
Flow and Return
NA
2 x 1
1/4”
BSP
Max Operating Pressure (PMS)
NA
3.0 bar
Operating Temparature Range
NA
60 - 80°C
Conventional Flue
0.05 +/- 0.02” WG
Operating Range
12.45 +/- 4.98 Pa
Water side resistance - mbar
10°C diff
NA
26
20°C diff
NA
8.3
Flue sockets - Dia. 145mm
Inside Flue Dia. 5” (125mm)