4-Wire Cord Connections (US Models Only)

1. Remove the screws securing the terminal block access cover and the strain

relief mounting bracket located on the back of the dryer upper corner.

2. Install a UL approved strain relief into the power cord entry hole of the

mounting bracket . Finger tighten the nut only at this time.

3. Remove the green neutral ground wire from the green ground screw located

above the terminal block.

Brass Terminal

Red

Tighten Nut to
These Threads

Power Cord

Strain Relief

Mounting Bracket

Green Ground

Screw

Neutral

Ground Wire

Terminal

Block

Black

Nut

Green Power Cord

Ground Wire

Black 240V

White Neutral

Red 240V

Green Ground

Typical Conductor

Receptacle

Typical 4

Conductor Cord

ELECTRIC Dryer

(RDE350AW)

14