Characteristic of the burners and nozzles – Hotpoint GQ64ST User Manual
Page 11

11
Characteristic of the burners and nozzles
Table 1
Liquid Gas
Natural Gas
Burner
Diameter
(mm)
Thermal Power
kW (p.c.s.*)
By-pass
1/100
(mm)
Nozzle
1/100
Flow*
g/h
Nozzler
1/100
Flow*
l/h
Nom.
Red.
(mm)
***
**
(mm)
Rapid (R)
100
3.00
0.7
41
86
218
214
116
286
Semi Rapid (S)
75
1.65
0.4
30
64
120
118
96
157
Auxiliary (A)
55
1.00
0.4
30
50
73
71
71
95
Supply
pressures
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
28-30
20
35
37
25
45
20
17
25
*
At 15°C and 1013 mbar-dry gas
**
Propane P.C.S. = 50.37 MJ/kg.
***
Butane P.C.S. = 49.47 MJ/kg.
Natural P.C.S. = 37.78 MJ/m
3