Appendix d – Hach 900 MAX User Manual
Page 137

Appendix D
Page 135
8990apdx_pulsecounts.fm
How to Calculate Pulses/Counts
Use the following examples to help you determine the value that you need to
enter when programming for sampling based on counts.
Example 1
You want to collect 24 samples over a 24-hour period on a 4–20 mA flow
proportional basis.
Average Flow Rate = 3.5 mgd (average flow rate over the 24-hour period)
Maximum Flow Rate = 10 mgd
a = 1440 minutes
1.
Calculate Q.
2.
Calculate t.
3.
Multiply Q x t x 10.
Therefore, the value entered for
INTV = _ _ _ _ CNTS
is 210.
Example 2
You want to collect 48 samples over a 24-hour period on a 4–20 mA flow
proportional basis.
Average Flow Rate = 1.75 mgd (average flow rate over the 24-hour period)
Maximum Flow Rate = 3 mgd
a = 1440 minutes
1.
Calculate Q.
2.
Calculate t.
3.
Multiply Q x t x 10.
Therefore, the value entered for
INTV = _ _ _ _ CNTS
is 175.
Example 3
You want to collect 96 samples over a 24-hour period on a 4–20 mA flow
proportional basis.
Average Flow Rate = 0.52 mgd (average flow rate over the 24-hour period)
Maximum Flow Rate = 2 mgd
a = 1440 minutes
1.
Calculate Q.
Q
Average Flow Rate
Maximum Flow Rate
------------------------------------------------------
3.5 mgd
10 mgd
---------------------
0.35 mgd
=
=
=
t
a
n
---
1440 min
24 samples
------------------------------
60 min/sample
=
=
=
0.35 mgd
60 min/sample
Ч
10
Ч
210
=
Q
Average Flow Rate
Maximum Flow Rate
------------------------------------------------------
1.75 mgd
3 mgd
-------------------------
0.583 mgd
=
=
=
t
a
n
---
1440 min
48 samples
------------------------------
30 min/sample
=
=
=
0.583 mgd
30 min/sample
Ч
10
Ч
174.9
=
Q
Average Flow Rate
Maximum Flow Rate
------------------------------------------------------
0.52 mgd
2.0 mgd
-------------------------
0.26 mgd
=
=
=