4
DIMENSIONS
The units are delivered fully assembled, tested and packed on a timber base with shockproof edges and protected by heat-shrunk plastic film.
On delivery and after unpacking, check the equipment for damage. For transport purposes, refer to the weights and dimensions given below.
TECHNICAL SPECIFICATION
D
G
F
E
J
H
B
A
K
C
C/2
HM 71
HM 101
Fuel
type
Natural gas / propane
Natural gas / propane
Maximum Input
kW
20 - 69.9
25 - 107 / 22 - 110
Maximum Output
kW
63.0
96.8
Maintenance loss at 60 °C of rated value
%
0.5
0.4
Total capacity
L
239.0
330.0
Primary circuit capacity
L
108.0
130.0
Hot water connection
Ø
1”
1”
Heating connection
Ø
1
1/2
”
1
1/2
”
Flue connection
Ø mm
150
150
Hot water tank heat exchange surface
m
2
3.14
3.95
Weight empty
Kg
282
335
Pressure drop primary circuit
mbar
46
83
A mm
B mm
C mm
D mm
E mm
F mm
G Ø mm
H mm
J mm
K mm
HM 71
1743
1630
680
937
680
390
150
1289
285
1720
HM 101
2093
2030
680
937
680
390
150
1693
285
2120