4. The wiring method should be in line with the local
wiring standard.
5. The power cable and connecting cable are self-
provided. All the cables shall have got the local
authentication certificate. During installation, when
the connecting cables break off, it must be assured
that the grounding wire is the last one to be broken
off.
6. The breaker of the air conditioner should be all-
pole switch; and the distance between its two contacts
should be no less 3mm. Such means for disconnection
must be incorporation in the fixed wiring.
7. The waste battery shall be disposed properly.
2
All electrical repairs must be carried out by
qualified electricians. Inadequate repairs may result
in a major source of danger for the user of the air
conditoiner.
Do not damage any parts of the air conditioner
that carry refrigerant by piercing or perforating the
air conditioner's tubes with sharp or pointed items,
crushing or twisting any tubes, or scraping the
coatings off the surfaces. If the refrigerant spurts
out and gets into eyes, it may result in serious eye
injuries.
Do not obstruct or cover the ventilation grille of
the air conditioner. Do not put fingers or any other
things into the inlet/outlet and swing louver.
Do not allow children to play with the air
conditioner. In no case should children be allowed
to sit on the outdoor unit.
Specifications
The refrigerating circuit is leak-proof.
1. Applicable ambient temperature range:
The machine is adaptive in following
situation
2. If the supply cord is damaged, it must be replaced
by the manufacturer or its service agent or a similar
qualified person.
3. If the fuse on PC board is broken please change it
with the type of T 3.15A /250VAC or T 25A/250VAC.
Please check the circuit diagram about the fuse
replaced.
Cautions
Cooling
Heating
Indoor
Outdoor
Indoor
Outdoor
Maximum:D.B/W.B
32 C/23 C
Minimum:D.B/W.B
18 C/14 C
Maximum:D.B
43 C/26 C
Minimum:D.B
Maximum:D.B
27 C
Minimum:D.B
20 C
Maximum:D.B/W.B
24 C/18 C
Minimum:D.B/W.B
-15 C
10 C/6 C