GC150 SERIES DIRECT VENT GAS APPLIANCE

Figure 9

Horizontal Termination Cap Locations

Dimension Descriptions

A

=

Clearance above the ground, a veranda,
porch, deck, or balcony - 12 inches (30 cm)
minimum.

B

=

Clearance to window or door that may be
opened - 9 inches (30 cm) minimum.

D

*

=

Vertical clearance to ventilated soffit located
above the terminal within a horizontal dis-
tance of 2 feet (60 cm) from the center-line of
the terminal - 18 inches (46 cm) minimum.

E

*

=

Clearance to unventilated soffit - 12 inches
(30 cm) minimum.

F

=

Clearance to outside corner - 9 inches as
tested.

G

=

Clearance to inside corner - 9 inches as test-
ed.

H• =

Not to be installed above a meter/regulator
assembly within 3 feet (90 cm) horizontally
from the center-line of the regulator.

I

=

Clearance to service regulator vent outlet - 6
feet (1.8 m) minimum.

J

=

Clearance to non-mechanical air supply inlet
to building or the combustion air inlet to any
other appliance - 12 inches (30 cm) mini-
mum.

K• =

Clearance to mechanical air supply inlet - 6
feet (1.8 m) minimum.

L+ =

Clearance above a paved sidewalk or paved
driveway located on public property - 7 feet
(2.1 m) minimum. Use of a CS will reduce
this dimension to as low as 12 inches (30
cm).

M# =

Clearance under veranda, porch deck, or bal-
cony - 12 inches (30 cm) minimum.

+

A vent must not terminate directly above a
sidewalk or paved driveway which is located
between two single family dwellings and
serves both dwellings.

#

Only permitted if veranda, porch deck, or bal-
cony is fully open on a minimum of 2 sides
beneath the floor.

As specified in Installation Codes. Note:
Local codes or regulations may require differ-
ent clearances.

*

30 inches/76 cm minimum distance required
for vinyl soffit materials.

As specified in CGA B149 Installation Codes
(1991). Note: Local Codes or Regulations
may require different clearances.

5. Termination Cap. Vent termination must not
be recessed into the wall or exterior sheeting.
Figure 9 illustrates termination cap locations and

minimum dimensions for each termination applica-
tion. Or, follow ANSI Z223.1, latest edition.