Frame loading limitations, Power supply load limitations, Module loading specifications – Harris Performance 7000 User Manual
Page 32
Chapter 1: Introducing the 6800/7000 Series of Frames
Installation Requirements
6
6800/7000 Series - Frames and Power Supplies Installation and Operation Manual
Frame Loading Limitations
Leitch 6800/7000 series frames are designed to operate in an ambient
temperature range of 0° to 50°C (32° to 122°F). No special provisions are
necessary other than power loading limitations that should be
considered upon installation.
There are two separate issues to consider with respect to a serial digital
product and its related loading limitations: power supply load
limitations and maximum frame loading limitations.
Power Supply Load Limitations
These are the maximum suggested loading specifications of the power
supply over the operating temperature range 32°F - 122°F
(0.5°C - 50°C). The 6800 series of power supplies come with 120 VAC,
240 VAC, and 48 VDC with inputs -6.5 V and +6.5 V output. Do not
parallel dissimilar supplies.
Module Loading Specifications
See
page 3 for information on power requirements for 6800/7000 series
serial products.
Power Supply Model #
+6.5 Rail Power Limit
-6.5 Rail Power Limit
6801PS
22 W
22 W
6804PS(-1)
78 W
29 W
7000PS
3.75 W
3.75 W
6801PS-48
22 W
22 W
6804PS-1-48
78 W
29 W