beautypg.com

Home Automation RC-1000 User Manual

Page 18

background image

1

1

8

8

Temperature Sensors

The Temperature Sensor settings are used to configure the internal temperature sensor and an optional remote
temperature sensor that is connected to the thermostat. When the internal sensor is enabled and the external
sensor is set to “Indoor”, the displayed temperature will be the average temperature of the two sensors.

Internal Sensor: This will enable or disable the onboard temperature sensor for indoor use only. *Enabled


External Sensor 1: This will enable the external temperature sensor for indoor or outdoor use. Indoor

temperatures are averaged between the sensors. *Disabled

Balance Setpoints (Dual Fuel Heat Pump)

The Balance Setpoints are used to determine when the auxiliary heat is used in a dual fuel heat pump system

If the outdoor temperature is above the “Upper Balance Setpoint” (45°F by default), the heat pump is used

exclusively.

If the outdoor temperature falls below the “Upper Balance Setpoint” but is above the “Lower Balance

Setpoint” (35°F by default) and if the heat pump is unable to heat at a rate of 5 degrees per hour or better,
the heat pump will turn off and the auxiliary heat will be used until the temperature rises above the “Upper
Balance Setpoint” or the call for heat has been satisfied.

If the outdoor temperature falls below the “Lower Balance Setpoint”, the heat pump will turn off and the

auxiliary heat will be used until the call for heat has been satisfied.

Factory Default

This option will restore all system settings and programming to factory fresh configuration. Read the warning
and then press [Yes] to proceed or [Cancel] to return to Installation Settings.