1.Fitting of the Mounting Plate and Positioning of the wall Hole

2.Making a Hole on the Wall and Fitting the Piping Hole Cover

When the mounting plate is first fixed

When the mounting plate is fixed side bar and lintel

1.Carry out, based on the neighboring pillars or lintels, a proper leveling for the plate to be
fixed against the wall, then temporarily fasten the plate with one steel nail.
2. Make sure once more the proper level of the plate, by hanging a thread with a weight
from
the central top of the plate, then fasten securely the plate with the attachment steel nail.
3. Find the wall hole location A using a measuring tape

A=170mm

35

Fit the level line

Refer to the previous article, " When the mounting plate is first fixed ", for the
position of wall hole.

Fix to side bar and lintel a mounting bar, Which is separately sold, and then fasten

the plate to the fixed mounting bar.

Make a hole of 70 mm in diameter,

slightly descending to outside the wall.

Install piping hole cover and seal it

off with putty after installation

(Section of wall hole)

Piping hole pipe

Outdoor side

Thickness
of wall

Indoor side

Wall hole

70mm

3.Installation of the Indoor Unit

Drawing of pipe

[ Rear piping ]

Draw pipes and the drain hose, then fasten them with the adhesive tape

[ Left

Left-rear piping ]

In case of left side piping, cut away, with a nipper, the lid for left piping.

In case of left-rear piping, bend the pipes according to the piping direction to the mark of hole for left-rear

piping which is marked on heat insulation materials.

3

G

Indoor unit

70mm