Communication objects, 1 device profile area, Chapter7 communication objects lists – Hitachi SJ2-CO User Manual
Page 27
CHAPTER7 COMMUNICATION OBJECTS LISTS
23
7.Communication Objects
Communication Objects are grouped 3 areas.
Index
Profile Area
1000-1FFF
Communication Profile Area
2000-5FFF
Manufacturer Specific Profile Area(Inverter's parameter area)
6000-9FFF
Device Profile Area
7.1 Device Profile Area
Supported Communication Object by CANopen interface option ( ) =initial value
Index
Sub-Index
Object name
Data type
Note
6007h
abort_connection_option_code
INTEGER16
*
6040h
control word
UNSIGNED16
*
6041h
status word
UNSIGNED16
*
6042h
vl_target_velocity
INTEGER16
*
6043h
vl_velocity_demand
INTEGER16
*
6044h
vl_control_effort
INTEGER16
*
6046h
vl_velocity_min_max_amount
UNSIGNED32
0
Number of entries(=2)
INTEGER8
*
1
vl_velocity_min_amount
UNSIGNED16
*
2
vl_velocity_max_amount
UNSIGNED16
6048h
vl_velocity_acceleration
Ramp
0
Number of entries(=2)
INTEGER8
*
1
delta_speed
UNSIGNED16
*
2
delta_time
UNSIGNED32
*
6049h
vl_velocity_deceleration
Ramp
0
Number of entries(=2)
INTEGER8
*
1
delta_speed
UNSIGNED16
*
2
delta_time
UNSIGNED32
*
6060h
modes_of_operation
INTEGER8
*
6061h
modes_of_operation_display
INTEGER8
*
Note : This object cannot store to EEPROM.