SF2600 burner Set up

7”

12½”

7¾”

12⅞”

SF2600 Oil burner Setup

Nozzle 80 Degree Solid Cone

Off Cycle Damper Setting (B) No. (as low as it goes

Flamelock Setting (A) No.

Combustion Air (C) No. to ¼

Draft - (Inches of water column) .06 to .08

Tests for CO² must be made without a fire in the wood/ coal firebox, and with all doors and draft controls

completely closed. The burner should be fired for several minutes prior to taking a reading. Normal CO²

reading is to with a stack temperature of 300 degrees or less. This would give you an efficiency of 84

to 85 percent.