32
Figure 7.10
H
1
V
1
V
2
USE SLP SERIES COMPONENTS ONLY
Two Elbows
Top Vent - Vertical Termination - (continued)
V
1
H
1
Maximum
V
2
V
1
+ V
2
Min.
Elbow only
Not allowed
*
*
*
6 in.
152 mm 2 ft. 610 mm
*
*
*
1 ft.
305 mm
4 ft.
1.22 m
*
*
*
2 ft.
610 mm
6 ft.
1.83 m
*
*
*
3 ft.
914 mm
8 ft.
2.44 m
*
*
*
4 ft.
1.22 m
12 ft. 3.66 m
*
*
*
5 ft.
1.52 m
16 ft. 4.88 m
*
*
*
V
1
+ V
2
+ H
1
= 36 ft. (10.97 m) Maximum
*No specific restrictions on this value EXCEPT
V
1
+ V
2
cannot exceed 32 ft. (9.75 m)
Note: A 6 in. (152 mm) section of straight flue
must be attached to the heater before a 90° elbow.
See also other documents in the category Heat & Glo Fireplace Kiln:
- 6000GCF-IPI (57 pages)
- Heat-N-Glo 6000XLS (43 pages)
- ST-HV-IPI (45 pages)
- 8000CL-IPI-T (82 pages)
- SL-750TV-IPI-E (47 pages)
- CFL-24LP-B (21 pages)
- HEAT & GLOW XLR-PB-AU (70 pages)
- VRT-BZ-N-AUB (76 pages)
- 6000TRS-CE (45 pages)
- SL-42 DVT (46 pages)
- CRESTFIRE CF550ENH (26 pages)
- EM-485T - 42 (53 pages)
- CRESCENT II (54 pages)
- CRESCENT II (52 pages)
- Heat & Glo Gas Fireplace ESC-42ST (68 pages)
- XLR-PLUS-N-AU (77 pages)
- RUTHERFORD 50 (48 pages)
- CF230E-B (24 pages)
- HEAT & GLO CF550E-B (26 pages)
- Heat & Glo 6000GL-IPI-S (67 pages)
- GRAND-I35 (43 pages)
- RED40 (78 pages)
- LCOR-HV-IPI (46 pages)
- Heat & Glo Fireplace 6000C (86 pages)
- 6000TR-OAK-IPI (31 pages)
- Heat & Glo Cosmo-130 (35 pages)
- 6000TV-OAK-IPI (20 pages)
- ST-38GTV (18 pages)
- CERONA-36 (65 pages)
- PIER-TVFL st-42tvfl (25 pages)
- 2197-980 (69 pages)
- Heat & Glo Fireplace AT-GRAND (23 pages)
- Heat-n- Glo BE-41 (31 pages)
- XLR-PB-CE (65 pages)
- EM-485T (52 pages)
- SL-550TV-D (43 pages)
- EVEREST (27 pages)
- HEAT & GLO SL-550 (1 page)
- HEAT & GLO TWILIGHT-II (37 pages)
- EXCLAIM-36H-C (46 pages)
- Soho24B 2137-900 (55 pages)
- HEAT & GLO BAY-40 (52 pages)
- 8000CFLP-OAKIPI (58 pages)
- HEAT & GLO Escape-42DVLP (61 pages)