SKU 95591/95592/95593

For technical questions, please call 1-800-444-3353

PAGE 9

TO 115 VOLT, gROUndEd

gFCI OUTLET

1/8”

AIR BLEEd HOLE

BASE

(25)

dISCHARgE PIPE

(nOT InCLUdEd)

CHECK VALVE

OR

UnIOn

(nOT InCLUdEd)

FIgURE E

o

1-1/4” OR 1-1/2”

n

PT PVC

3. Connect the Discharge Pipe to the Base (25).

nOTE: Make sure the Discharge

Pipe is secured to a solid surface, with appropriate hardware (not included), to

ensure the stability of the Pump.

(See Figure E.)

Install an additional union (not included) or other means of separating the Dis-

4.

charge Pipe just above the floor to facilitate removal of the Pump if necessary.

(See Figure E.)
A check valve (not included) is recommended just above, or in place of, the union

5.

to prevent the backflow of water after each pump cycle. If a Check Valve is used,

a

1/8” diameter air bleed hole should be drilled through the Discharge Pipe just

above the lower Base (25) to prevent Pump “airlock”. A small spray of water out of

this hole is normal while the Pump is running.

(See Figure E.)