Top Vent - Vertical Termination (continued)

Figure 7.11

Two Elbows

Figure 7.10

4. Center the Flue Restrictor on vent and secure in place

by using two self-tapping screws (see Figure 7.10).

5. Reinstall the Exhaust Shield.

3. Match the amount of vertical you have in the system

with the chart to fi nd the appropriate position to set the
Flue Restrictor (see Figure 7.9).

Figure 7.9

1 2 3 4 5

SETTING

1 2 3 4 5

Vertical

TOP VENT

REAR VENT

NG

LP

NG

LP

4 ft.

1-1

No

Restrictor

No

Restrictor

No

Restrictor

8 ft.

2-2

1-2

1-1

No

Restrictor

15 ft.

3-3

3-2

2-2

1-2

20 ft.

3-4

3-3

3-3

2-3

25 ft.

3-4

3-3

3-3

2-3

30 ft.

4-4

3-4

3-4

3-3

35 ft.

4-4

3-4

3-4

3-3

40 ft.

5-4

4-4

4-4

3-4

Note: If the DVP-2SL adapter and SLP pipe is used, you

MUST subtract one number from the table above.

Example: Top vent 40 ft vertical with DVP pipe = 5-4

Top vent 40 ft vertical with SLP pipe = 4-3

V

1

H

1

Maximum

V

2

V

1

+ V

2

Min.

Elbow only

2 ft.

610 mm

*

*

*

6 in.

152 mm

6 ft.

1.8 m

*

*

*

2 ft.

610 mm

11 ft.

3.4 m

*

*

*

3 ft.

914 mm

16 ft.

4.9 m

*

*

*

4 ft.

1.2 m

20 ft

6.1 m

*

*

*

V

1

+ V

2

+ H

1

= 50 ft (15.2 m) Maximum

*No specifi c restrictions on this value EXCEPT

V

1

+ V

2

+ H

1

cannot exceed 50 ft (15.2 m)