14 installation, Changing to natural gas – Harman Stove Company Conquest Gas Stove User Manual
Page 14
14
INSTALLATION
Only For Qualified Installers
Changing to Natural Gas
Remove pilot tower with
a 7/16” wrench. Replace
LP orifice with Natural
Gas orifice. See
instructions in kit.
Use a 1/2” deep well
socket to remove the LP
#53 orifice and replace
with the #37 Natural gas
orifice from the kit.
Natural Gas Kit
Part No. 1-00-09112
NG Conversion label
NG Orifice #37
NG Valve
Conversion
Module
NG Conversion
Instructions
This kit is only for use in the Conquest direct
vent gas stove.
Natural Gas Conversion Kit
NG Pilot Orifice
Remove the three screws that hold the
LP knob module in place. Remove the
module and replace with the Natural
gas module from the kit. See kit
instructions.
Remove four
bolts and
remove burner
module from
stove.
3
1
2
4