beautypg.com

7. lift-arc tig procedure, 1. routine maintenance, 3 months – Hobart Welding Products STELLAR AT OM-2208 User Manual

Page 24: 6 months

background image

OM-2208 Page 20

4-7. Lift-Arc TIG Procedure

With Process Switch in the Lift-Arc
TIG position, start an arc as follows:

1

TIG Electrode

2

Workpiece

Touch tungsten electrode to work-
piece at weld start point, hold
electrode to workpiece for 1-2
seconds
, and slowly lift electrode.
An arc will form when electrode is
lifted.

Normal open-circuit voltage is not
present before tungsten electrode
touches workpiece; only a low
sensing voltage is present between
electrode and workpiece. The
solid-state output contactor does
not energize until after electrode is
touching workpiece. This allows
electrode to touch workpiece with-
out overheating, sticking, or getting
contaminated.

1

1 – 2

Seconds

“Touch”

Do NOT Strike Like A Match!

2

Ref. S-156 279

SECTION 5 – MAINTENANCE & TROUBLESHOOTING

5-1. Routine Maintenance

Y

Disconnect power
before maintaining.

.

Maintain more often
during severe conditions.

3 Months

Replace

Damaged Or

Unreadable

Labels

Replace Cracked

Torch Body

Repair Or

Replace

Cracked

Cables

Repair Or Replace

Cracked Cables

And Cords

Clean

And

Tighten Weld

Connections

6 Months

Blow Out Inside