Burners and nozzle specifications – Hotpoint GC640 User Manual
Page 9
9
Burners and Nozzle Specifications
**
At 15°C and 1013 mbar-dry gas
**
Propane P.C.S. = 50.37 MJ/kg.
***
Butane P.C.S. = 49.47 MJ/kg.
Natural P.C.S. = 37.78 MJ/m
3
Gas Section: Class
II2H3+
Rated Power kW (1)
7,8 (567gr/h-G30)
(557gr/h-G31)
(1) Values in g/h refer to capacities with liquid
gas (Butane, Propane).
It is the law that all gas appliances are installed by competent persons in accordance with the currect edition of the Gas
Safety (Installation and Use) Regulations. It is in your interest and that of safety to ensure compliance with the law.
In the UK, CORGI registered installers work to a safe standard of practice.
The hob must be installed in accordance with BS6172:
Failure to install the hob correctly could invalidate the warranty liability claims and could lead to prosecution.
Table 1
Liquid Gas
Natural Gas
Burner
Diameter
(mm)
Thermal power
kW (p.c.s.*)
By-Pass
1/100
Nozzle
1/100
Flow*
g/h
Nozzle
1/100
Flow*
l/h
Nomin.
Ridot.
(mm)
(mm)
***
**
(mm)
Fast (R)
100
3,00
0,70
41
86
218
214
116
286
Semi Fast (S)
75
1,90
0,40
30
70
138
136
106
181
Auxiliary (A)
55
1,00
0,40
30
50
73
71
79
95
Supply
Pressures
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
28-30
20
35
37
25
45
20
17
25