4

• Setting the burners to minimum:
1. Turn the tap to the low flame position.

2. Remove the knob and adjust

the adjustment screw, which is

positioned in or next to the tap pin,

until the flame is small but steady.

3. Having adjusted the flame to the required low setting,

while the burner is alight, quickly change the position of

the knob from minimum to maximum and vice versa

several times, checking that the flame does not go out.

4. Some appliances have a safety device (thermocouple)

fitted. If the device fails to work when the burners are set

to the low flame setting, increase this low flame setting

using the adjusting screw.

5. Once the adjustment has been made, replace the seals

on the by-passes using sealing wax or a similar

substance.

! If the appliance is connected to liquid gas, the regulation

screw must be fastened as tightly as possible.
! Once this procedure is finished, replace the old rating

sticker with one indicating the new type of gas used.

Stickers are available from any of our Service Centres.
! Should the gas pressure used be different (or vary slightly)

from the recommended pressure, a suitable pressure

regulator must be fitted to the inlet pipe (in order to comply

with current national regulations).