beautypg.com

Safety precautions – haier AD182AMBEA(ECO) User Manual

Page 6

background image

5

2. If the supply cord is damaged, it must be replaced by the manufacturer or its service

agent or a similar qualified person.

3. If the fuse on PC board is broken please change it with the type of T 3.15A /250VAC.

4. The wiring method should be in line with the local wiring standard.

1. Applicable ambient temperature range:

The machine is adaptive in following situation

5. The power cable and connecting cable are self-provided. The power cable parameter

is:

1) H07RN-F 5G 2.5mm

2

(380-400V, 3N~, 50Hz),(AD42NAMBEA(ECO)

AD36NAMBEA(ECO)AD28NAMBEA(ECO) ) ;

2) H05RN-F 3G 4.0mm

2

(1PH,220-230V~,50Hz)(AD28NAMBEA(ECO)

AD242AMBEA(ECO));

3) H05RN-F 3G 2.5mm

2

(1PH,220-230V~,50Hz)(AD182AMBEA(ECO)).

The connecting cable should be H05RN-F 4x0.75mm

2

All the cables shall have got the European authentication certificate. During installation,

when the connecting cables break off, it must be assured that the grouding wire is the

last one to be broken off.

6. The breaker of the air conditioner should be all-pole switch; and the distance between

its two contacts should be no less 3mm.

7. The indoor unit installation height is at least 2.5m.

8. The air breaker and the power switch should installed the converiently reachable place

for user.

Safety Precautions

Cooling

Heating

Indoor

outdoor

Rated Maximum Minimum
27 32 18
19 23 14
35 43 10
24 26 6
20 27 15
15 -- --
7 24 -7
6 18 --

DB C
WB C
DB C
WB C

Indoor

outdoor

DB C
WB C

DB C
WB C