beautypg.com

Holmes 90 Oscillating AccuTempTM Heater HFH595-CN User Manual

Page 2

background image

PLEASE READ AND SAVE

THESE IMPORTANT

SAFETY INSTRUCTIONS

When using electrical appliances, basic safety precautions should

always be followed to reduce the risk of fire, electric shock, and

injury to persons, including the following:
1. Read all instructions before using the appliance.
2. To avoid fire or shock hazard, plug the appliance directly into

a 120V AC electrical outlet.

3. The heater is hot when in use. To avoid burns, DO NOT let bare

skin touch hot surfaces. If provided, use handles when moving

this heater. Keep combustible materials, such as furniture, pillows,

bedding, papers, clothes, and curtains at least 3 ft (0.9 m) from

the front of the heater and keep them away from the sides and rear.

4. DO NOT run cord under carpeting. DO NOT cover cord with throw

rugs, runners, or the like. Arrange cord away from traffic area and

where it will not be tripped over.

5. This heater is not intended for use in bathrooms, laundry areas

and similar indoor location. NEVER locate heater where it may

fall into a bathtub or other water container.

6. Extreme caution is necessary when any heater is used by,

or near children or invalids, and whenever the heater is left

operating and unattended.

7. Always unplug the heater when not in use.
8. When unplugging, be sure to pull by the plug and not the cord.
9. DO NOT insert or allow foreign objects to enter any ventilation

or exhaust opening as this may cause an electric shock or fire,

or damage the heater.

10.DO NOT operate heater with a damaged cord or plug, or after the

heater malfunctions, has been dropped or damaged in any manner.

Return appliance to manufacturer for examination, electrical or

mechanical adjustment, or repair.

11.A heater has hot and arcing or sparking parts inside.

DO NOT use it in areas where gasoline, paint, or flammable

liquids are used or stored.

12.Use appliance only for intended household use as described

in this manual. Any other use not recommended by the

manufacturer may cause fire, electric shock, or injury to persons.

The use of attachments not recommended or sold by The Holmes

Group may cause hazards.

13.DO NOT use outdoors.

14.To prevent a possible fire, DO NOT block air intakes or exhaust

in any manner. DO NOT use on soft surfaces, like a bed, where

openings may become blocked.

15.To disconnect heater, turn controls to OFF, then remove plug

from outlet.

16.Avoid the use of an extension cord because the extension cord

may overheat and cause a risk of fire. However, if you have

to use an extension cord, the cord shall be No. 14 AWG minimum

size and rated not less than 1875 watts.

17.If the heater will not operate, see specific instructions on

Auto Safety Shut-off.

18.DO NOT attempt to repair or adjust any electrical or mechanical

functions on this unit. Doing so will void your warranty. The inside

of the unit contains no user serviceable parts. All servicing should

be performed by qualified personnel only.

PLEASE READ AND SAVE

THESE IMPORTANT

SAFETY INSTRUCTIONS

THIS PRODUCT IS EQUIPPED WITH A POLARIZED AC

(Alternating Current)PLUG (a plug having one blade wider

than the other). This plug will fit into the power outlet

only one way. If the plug does not fit fully into the outlet,

reverse the plug. If it still does not fit, contact qualified

personnel to install the proper outlet.

DO NOT DEFEAT THE SAFETY PURPOSE OF THIS

POLARIZED PLUG IN ANY WAY.

PRE-OPERATING INSTRUCTIONS

CLEANING/MAINTENANCE

During Season Care:
Always unplug the heater, before moving or cleaning.
1. Carefully wipe the unit with a soft, damp cloth. Please

be very cautious near the motor and heating elements.

2. After cleaning, be sure to completely dry the unit with

a cloth or towel.

After Season Care:
1. Store heater in a cool, dry location.
2. Holmes recommends that you store the unit in its original carton.

1. Carefully remove your heater from the box.

(please save the carton for off-season storage).

2. Make sure the unit is in the OFF position before plugging

the heater into the outlet.

3. Place heater on firm level surface.

4. Avoid overloading your circuit by not using other high wattage

appliances in the same outlet. At 1500 Watts, this unit draws

12.5 Amps.

ILLUSTRATIONS

A. POWER LIGHT

B. MODE CONTROL

C. LCD DISPLAY

SCREEN

D. OSCILLATION

SWITCH

E. CARRY GRIP

F. OSCILLATION BASE

G. TEMPERATURE SET

BUTTON

H. MANUAL/ACCUTEMP

SWITCH

Figure 1

A

B

H

C

D

G

E

F

25

Figure 2

HEAT CONTROLS

OFF
FAN
LOW 500W
MED 1000W
HI 1500W

TROUBLESHOOTING

If your heater fails to operate:
• Make sure the electrical outlet or circuit breaker is working.
• Check for obstructions. If you find an obstruction turn the heater OFF,

and unplug the unit. Carefully remove the obstruction and follow the

reset instructions.

• The thermostat might be set too low. Adjust the thermostat until the

heater restarts.

• Make sure selector is in LO, MED, or HI setting.

If your heater fails to oscillate:
• Make sure the oscillation button is pressed.
Incorrect Room Temperature Display:
1. Allow a few minutes for the heater to adjust to the room

temperature.

2. Switch unit to Accutemp. Use touch pad to set desired temperature.

Please DO NOT attempt to open or repair the heater.

Please see the Warranty for Service Instructions.

This heater is equipped with a patented, technologically-advanced safety

system that requires the user to reset the heater if there is a potential

overheat situation. When a potential overheat temperature is reached,

the system will automatically shut the heater off. It can only resume

operation when the user resets the unit.

To Reset the Heater:
1. Turn MODE to off and slide switch to manual.
2. Unplug the heater and wait 10 minutes for the unit to cool down.
3. After the 10 minutes, plug the unit in again and operate normally.

ACCUTEMP™ DIGITAL THERMOSTAT

Your heater is equipped with an AccuTemp™ Digital Thermostat

that allows you to set your heater to your precise comfort level.
Setting the AccuTemp™ thermostat:
1. Make sure the Manual/AccuTemp™ switch is set to AccuTemp™.

The LCD display will read 25°.

2. Turn the mode control to LO, MED or HI.
3. Push the temperature set button until the display reads your desired

temperature. To increase the temperature push the top button, for

lower temperatures push the lower button. When finished setting the

temperature, release the button and the display will flash to indicate

the thermostat will be set to that temperature.

4. The display will return to existing room temperature and gradually

increase until the room has reached your pre-set temperature.

5. If the unit will not start in the AccuTemp™ mode, please make sure

the “set temperature” is higher than the current room temperature.

NOTE: It is normal for the heater to cycle ON and OFF as it maintains

the preset temperature. To prevent the unit from cycling, you need

to raise the thermostat setting. When the preset temperature is made,

the fan will run for 30 seconds without heat. This cool down process

ensures an accurate and consistent temperature reading. If you unplug

the heater, you will have to reset the AccuTemp™ thermostat again by

following the above instructions.
Manual Operation:
1. If you want the heater to run continuously, turn the

Manual/AccuTemp

switch to Manual and adjust the

mode control to LO, MED or HI.

AUTO SAFETY SHUT-OFF WITH CERAMIC CONTROL

A

B

C

H

G

D