OPERATING INSTRUCTIONS

1. Turn the Power knob to the desired setting (Off-High-

Low).

2. When the desired humidity level is reached the speed

control can be set to the Low setting to reduce the

humidification rate.

NOTE: Allow up to 30 minutes for the filter to fully absorb

water and the unit to produce the maximum moisture

output.
3. When the water tank is empty and the water in the

base is almost empty, you need to refill the tank. The

fan will continue to run to help dry the humidifier.

Switch off and unplug the unit. Please follow the

Daily Cleaning instructions before refilling the water

tank.

4. Refill the tank as directed in the Pre-Operating

Instructions.

If you do not plan to use the humidifier for two or more

days, make sure any residual water is drained from the

water tank, base and wick filter to prevent algae or

bacteria growth.

REPLACING THE FILTER

Through normal use, waterborne minerals and sediment

become trapped in the wick filter. The harder your water,

the greater the amount of minerals in the water, and the

more often you will need to change your filter. In general,

a brown filter indicates a need to replace the filter.
You will be able monitor the condition of the filter in your

humidifier by checking the FilterCheck

®

Indicator. When the

unit is off or empty of water the FilterCheck

®

will read in

the OFF/FILL position.
NOTE: Within 60 minutes of use the FilterCheck

®

will move

from the OFF position and indicate your filter condition.
A brand new filter will register in the section reading GOOD

filter. After frequent use of your humidifier, the FilterCheck

®

indicator will let you know when the filter should be

changed. When the needle is in the CHANGE section this

means the proper amount of moisture is not getting into

your air due to the large amount of minerals and sediment

that have become trapped in your filter. At this point you

should replace your filter. It is important to change your

filter to get the best performance from your humidifier.

To replace the filter, follow the below steps.

1. Turn the power switch off and unplug the humidifier

from the electrical outlet.

2. Remove the tank and main housing to access the

base tray.

3. Discard the old filter and follow weekly cleaning

instructions.

4. Insert a new filter into the filter support in the base.
5. Replace the main housing

and then the tank.

6. Repeat Operating

Instruction steps.

It will take about 30 minutes

for the humidifier to reach

maximum output.
You can purchase replacement

filters model (HWF62) by

calling 1-800-546-5637 or visiting

www.holmesproducts.com.

CLEANING AND MAINTENANCE
INSTRUCTIONS

Humidifiers provide comfort by adding moisture to dry

indoor air. To get the most of the benefit from the

humidifier and avoid product failure, follow all

maintenance instructions carefully. If the recommended

care and maintenance guidelines are not followed,

micro-organisms may be able to grow in the water within

the humidifier.

Daily Maintenance

1. Before cleaning, set the control switch to OFF position

and unplug the unit from the electrical outlet.

2. Lift off the tank and the housing of the humidifier.
3. Carry the base and the tank to the sink, remove the wick

filter, then drain and rinse the base and tank thoroughly

to remove any sediment and dirt. Wipe clean and dry

with a clean soft cloth or paper towel. (DO NOT use

metal cleaning utensils or abrasive cleaners)

4. Put the filter back in the filter supports, replace the

housing, then refill the tank with cool tap water as

instructed in filling the water tank instructions.

Weekly Maintenance

Remove scale:
1. Repeat steps 1-3 above.
2. Clean the base by partially filling the base with one

8-oz cup of undiluted white vinegar, or by using

Cleanse Clean

®

solution (Model S1710) by the

manufacturer. Let solution stand 20 minutes, clean all

interior surfaces with a soft brush.

3. Dampen a cloth with undiluted white vinegar and

wipe out entire base to remove scale.

4. Rinse with clean warm water to remove scale and the

white vinegar solution before beginning to disinfect the

tank.

Disinfect tank:
1. Fill tank with

1

/

2

teaspoon of chlorine bleach and

1

/

2

gallon of water.

2. Let the solution stand for 20 minutes, swishing every

few minutes. Wet all surfaces.

3. Empty the tank after 20 minutes, and rinse well with

water until the bleach smell is gone. Dry with a clean

cloth or paper towel.

4. Refill the water tank with cool water; replace the housing

and the water tank. Repeat ALL Operating Instructions.

STORAGE INSTRUCTIONS

When not using your humidifier for an extended period

of time:
1. Dispose of the filters. DO NOT leave in unit.

2. Clean, rinse and thoroughly dry the humidifier as

directed in weekly maintenance. DO NOT leave any water

in the unit when storing. Leaving water in the unit may

render the unit inoperable for the following season.

3. Place the humidifier in the original carton and store in a

cool, dry place.

4. Order your replacement filter for next year’s use.

21. Never place housing under water flow or immerse in

liquids.

22. Do not plug in the cord with wet hands: electric shock

could result.

23. Do not pour water in any openings other than the

water tank.

24. To prevent damage to surfaces, do not place

humidifier under overhanging surfaces.

25. NEVER operate unit without water in the tank.
26. Do not move unit after it has been used until unit

cools completely.

27. Use both hands when carrying full tank of water.

PLEASE READ AND SAVE

THESE IMPORTANT SAFETY

INSTRUCTIONS

Consumer Safety Information

NOTE: This is an electrical appliance and requires

attention when in use.
NOTE: If moisture forms on the walls or windows of the

room, turn off the humidifier. The room already has

plenty of humidity and additional moisture may cause

damage.
NOTE: DO NOT block air inlet or outlet.

Cord and Plug Installation Safety Instructions

The length of cord used on this appliance was selected to

reduce the hazards of becoming tangled in, or tripping

over a longer cord. If a longer cord is necessary an

approved extension cord may be used. The electrical

rating of the extension cord must be equal to or greater

than the rating of the humidifier (refer to the rating

artwork placed on the humidifier). Care must be taken to

arrange the extension cord so that it will not drape over

the countertop or tabletop where it can be pulled on by

children or accidentally tripped over.

HOW COOL MIST WORKS

Your Holmes

®

Cool Mist humidifier draws dry air through

the rear air intake grill area. This air is then passed

through a moisture–laden wick filter, which retains the

minerals and deposits in the water. The resulting moist air

is directed back into the room from the top air grill.
NOTE: This humidification system provides a cool, invisible

moisture output. It is normal not to see the mist.
NOTE: A humidity level below 20% can be unhealthy and

uncomfortable. The recommended humidity level is between

40%-50%.

PRE-OPERATING INSTRUCTIONS

1. Be sure the humidifier is disconnected from the

electrical outlet and the switch is in the OFF position.

2. Select a location for your humidifier, on a flat

surface, about 4 inches (10 cm) away from the wall.

Do not place your humidifier on furniture; a floor

location that will not be damaged by moisture is best.

3. Remove the water tank by holding the tank handle

and lifting straight upward (see figure 2).

4. Remove the main housing by lifting straight upward.

Check to see that the wick filter is properly in place.

Replace the humidifier housing.

FILLING THE WATER TANK

NOTE: This humidifier holds about 1 gallon of water in the

tank and humidifier base. The humidifier will produce up to

2.5 gallons of moisture over a 24-Hour period, depending

on the room humidity and temperature.
1. Be sure the humidifier is disconnected from the

electrical outlet.

2. Remove the tank from the base by holding the

handle and lifting straight up (see figure 2).

3. Twist off the tank cap located on the bottom of the

tank by turning counter clockwise and fill the water

tank with cool, fresh water.
Do not fill with warm water as this may

cause leaking.

4. After filling the tank, replace the tank cap by firmly

turning clockwise and then replace the water tank on

the base. The tank will immediately begin to empty

into the base.

5. Plug the power cord into a 120V AC electrical outlet.

P L E A S E R E A D A N D S AV E T H E S E

I M P O R TA N T S A F E T Y I N S T R U C T I O N S

F E AT U R E S - O P E R AT I O N S

When using electrical appliances, basic safety precautions

should always be followed to reduce the risk of fire,

electric shock, and injury to persons, including the following:
1. Read all instructions before using the appliance.
2. To avoid fire or shock hazard, plug the appliance

directly into a 120V AC electrical outlet.

3. Keep the cord out of heavy traffic areas. To avoid

fire hazard, NEVER put the cord under rugs or near

heat registers.

4. DO NOT place humidifier near heat sources such as

stoves, radiators, and heaters. DO locate your

humidifier on an inside wall near an electrical outlet.

The humidifier should be at least 4 inches (10 cm)

away from the wall for best results.

5. NEVER place humidifier in an area where it is

accessible to children. NEVER use humidifier in a

closed room, particularly where a child may be

sleeping, resting, or playing (a closed room may

result in excessive humidity).

6. WARNING: Do not attempt to refill humidifier

without first unplugging the unit from its electrical

outlet. Failure to heed this warning may cause

personal injury. Be sure to unplug the unit by pulling

on the plug and not the cord.

7. Never place anything over moisture outlet when the

unit is running.

8. NEVER drop or insert any object into any openings.
9. DO NOT operate any appliance with a damaged cord

or plug, after the appliance malfunctions, or if it has

been dropped or damaged in any manner. Return

appliance to manufacturer for examination, electrical

or mechanical adjustment, or repair.

10. Use appliance only for intended household use as

described in this manual. Any other use not

recommended by the manufacturer may cause fire,

electric shock, or injury to persons. The use of

attachments not recommended or sold by the

manufacturer may cause hazards.

11. DO NOT use outdoors.
12. Always place humidifier on a firm, flat, level surface.

A waterproof mat or pad is recommended for use

under the humidifier. NEVER place it on a rug or

carpet, or on a finished floor that may be damaged

by exposure to water or moisture.

13. DO NOT allow the Moisture Outlet to directly face the

wall. Moisture could cause damage, particularly to

wall paper.

14. Humidifier should be unplugged when not in use.
15. NEVER tilt, move, or attempt to empty unit while it is

operating. Shut off and unplug before removing the

water tank and moving the unit.

16. This humidifier requires daily and weekly

maintenance to operate appropriately. Refer to daily

and weekly cleaning procedures. Use only cleaners

and additives recommended by the manufacturer.

17. NEVER use detergents, gasoline, glass cleaner,

furniture polish, paint thinner, or other household

solvents to clean any part of the humidifier.

18. Excessive humidity in a room can cause water

condensation on windows and some furniture. If this

happens, turn the humidifier OFF.

19. Do not use humidifier in an area where humidity

level is in excess of 50%. Use a hygrometer,

available at your local retailer or through the

manufacturer, to measure the humidity.

20. DO NOT attempt to repair or adjust any electrical or

mechanical functions on this unit. Doing so will void

your warranty. The inside of the unit contains no user

serviceable parts. All servicing should be performed

by qualified personnel only.

F E AT U R E S - O P E R AT I O N S

C L E A N I N G / M A I N T E N A N C E

S T O R A G E I N S T R U C T I O N S

THIS APPLIANCE HAS A POLARIZED PLUG (one blade is wider than the

other). To reduce the risk of electric shock, this plug is intended to fit in a

polarized outlet only one way. If the plug does not fit fully in the outlet,

reverse the plug. If it still does not fit, contact a qualified electrician to

install the proper outlet.

DO NOT ATTEMPT TO MODIFY THIS PLUG OR DEFEAT THIS

SAFETY FEATURE IN ANY WAY.

A. Circular Filter

Supports

B. Circular

Extended Life

Wick Filter

C. Humidifier Base

B

A

C

Figure. 1

A. Humidifier Tank
B. Carry Handle
C. Humidifier

Housing

D. 2-Speed

Humidity

Control/Power

Knob

E. Humidifier Base
F. FilterCheck

®

Indicator

A

B

C

D

E

F

Figure. 2

If you have any questions regarding your product or
would like to learn more about other Holmes

®

products, please contact our Consumer Service
Department at 1-800-546-5637 or visit our website at
www.holmesproducts.com.

Figure 3

HM1281_08EM1.qxd:HM1281_08EM1.qxd 5/8/08 10:15 AM Page 2