REMOTE CONTROLS: Up/Down Volume, Up/Down Tuning, Preset Next, Preset ‘1 ‘, Preset ‘11’: Audio/

Video Input Selectors, Tape 1, Tape 2/EPL, Power, AM/FM Selector, Tone In, Mute.

CONVENIENCE OUTLETS:

120 VAC MODELS: 1 Polarized Unswitched, 2 Polarized Switched, 1 Grounded Switched

240 VAC MODELS: 1 Reverse-IEC Unswitched, 2 Reverse-IEC Switched

PHYSICAL DIMENSIONS:
17” Wide x

Deep x

High (excluding feet); Faceplate 17” or 19” Wide

43.2 cm Wide x 29.5 cm Deep x 6.3 cm High (excluding feet); Faceplate 43.2 cm or 48.3 Wide

POWER CONSUMPTION (Excluding Convenience Outlets): 20 watts Max.

INSTALLATION

RACKMOUNTING

VENTILATION/

PLACEMENT

LINE VOLTAGE

The 945 Preamp/Tuner is supplied in either a 17” Black Version, or a 19” Silver Version. The 19” model

has rackmounting holes provided for installation in equipment racks. The holes are on standard EIA

spacings, though the faceplate height is not standard EIA size.

The 945 produces very little heat during operation, and therefore requires no special considerations for
ventilation. The preamp/tuner should be located at least several inches away from components that
contain large power transformers (such as power amplifiers), due to the possibility of audible hum or buzz
from magnetic radiation.

The 945 Preamp/Tuner is available in either 120 VAC or 240 VAC, 50/60 Hz versions . Make sure that
the unit is configured for your local AC line voltage before attempted use. The configuration is labelled
directly above the power cord entry point.

OPERATION/CONNECTIONS

POWER

C

ORD

CONNECTION

CONVENIENCE

OUTLETS

Units wired for 240 VAC are supplied without AC power cords. Local agents will supply cords with male

connectors appropriate to the local standard.

Units wired for 120 VAC are supplied with a detachable AC power cord. The female connector plugs

into the receptacle provided on the rear panel. This power cord is a standard

IEC Type 320, 3-wire, 16

gauge assembly. Should replacement ever be necessary, be sure to replace it with an identical cord.

Never remove the grounding pin from the male end of the cord. In applications where a grounded wall
outlet is not available, a ground adaptor should be employed, with the ground tab or wire of the adaptor
connected to a suitable earth ground.

Units wired for 720 VAC have a total of four outlets for connection of associated components. The

polarized Unswitched Outlet is powered at all times, which should generally be used for a turntable or

tape deck. The remaining three Switched Outlets (one grounded, two polarized) are powered when the

Power Switch is engaged, as indicated by the switch’s green light. The grounded outlet is provided for
equipment requiring a grounded connection.

Units wired for 240 VAC have a total of three reverse-IEC outlets for connection of associated com-

ponents. The Unswitched Outlet is powered at all times, which should generally be used for a turntable
or tape deck. The remaining two Switched Outlets are powered when the Power Switch is engaged, as
indicated by the switch’s green light.

for all models, the maximum power available from the Unswitched Outlet is 200 watts. The maximum

total power available from the Switched Outlets is 800 watts. This total power may be drawn from a single
outlet, or a combination of outlets. Since some power amplifiers consume more than 800 watts at

maximum output, check the power amplifier’s rating before connecting to these convenience outlets.

-5-

IEC Type 320, 3-wire, 16