Electrical Connection

! THIS APPLIANCE MUST BE EARTHED.

The hob is designed to work with alternating current,

the supply voltage and frequency indicated on the

rating plate (situated under the hob). Make sure that

the local supply voltage corresponds to the voltage

indicated on the rating plate.

Connecting the supply cable to the mains

electricity supply

For models supplied without a plug, fit a standard

plug suitable for the load indicated on the rating plate,

onto a cable and connect to a suitable socket. To

connect direct to the mains supply, a double pole

switch with a contact separation of at least 3mm

suitable for the load and complying with current

standards and regulations must be fitted between the

appliance and the mains supply outlet.

The green-yellow earth wire must not be interrupted

by the switch.

The supply cable must be positioned so that no part of

it reaches a temperature of 50°C above room

temperature. For installation above a built-under oven,

the hob and the oven must be connected separately

to the electricity supply, both for safetly reasons and

for easy removal of the oven for repair, maintenance

etc.

DO NOT use adapters as they could cause

overheating or burning.

Before connecting to the power supply, make sure

that:

• the limiter switch and the domestic system can

withstand the load from the appliance (see rating

plate).

• the supply system is efficiently earthed according

to standards and laws in force.

• the socket or double-pole switch are easily

accessible when the appliance is installed.

! The wires in the mains lead are coloured in

accordance with the following code:

Green & Yellow

- Earth

Blue

- Neutral

Brown

- Live

As the colours of the wires in the mains lead may not

correspond with the coloured markings identifying the

terminals in your plug, proceed as follows:

Connect the Green & Yellow wire to terminal marked
“E” or

or coloured Green or Green & Yellow.

Connect the Brown wire to the terminal marked “L” or

coloured Red or Brown.

Connect the Blue wire to the terminal marked “N” or

coloured Black or Blue.

FAILURE TO OBSERVE THE ACCIDENT-PREVENTION

REGULATIONS RELIEVES THE MANUFACTURER OF

ALL LIABILITY.

Replacing the cable

Use a rubber cable of the type H05RR-F with a

suitable cross section 3 x 0.75 mm².

The yellow-green earth wire must be 2-3 cm longer

than the other wires.