GB

DATA PLATE

Dimensions

width cm 43.5
height cm 32
depth cm 41.5

Volume

lt. 58

Dimensions of
models with
removable racks

width cm 37.5
height cm 32
depth cm 41.5

Volume of models
with removable
racks

lt. 50

Electrical
connections

voltage: 220-230V ~ 50/60 Hz or
50Hz (see data plate)
maximum power absorbed 2250W

Directive 2002/40/EC on the label
of electric ovens.
Standard EN 50304

ENERGY LABEL

Energy consumption for Natural
convection – heating mode:
Convection mode

Declared energy consumption for
Forced convection Class – heating
mode: Multi-cooking

This appliance conforms to the
following European Economic
Community directives:
- 2006/95/EEC of 12/12/06 (Low
Voltage) and subsequent
amendments;
-89/336/EEC of 03/05/89
(Electromagnetic Compatibility) and
subsequent amendments;
- 93/68/EEC of 22/07/93 and
subsequent amendments.
- 2002/96/EC

Electrical connection

The electrical connection to the mains must be made

on the appliance. The power voltage and frequency

are as indicated on the rating plate.

! THIS APPLIANCE MUST BE EARTHED.

Connecting the power supply cable

To open the terminal board:

• Using a screwdriver, press on the tabs situated

on each side of the terminal board cover.

• Pull open the terminal board cover.

To connect the power supply cable, proceed as

follows:

_ Unscrew the cable clamp screw and the contact

screws L-N-$.

• Fasten the wires beneath the screwheads using

the following colour scheme: Blue (N) Brown (L)

Yellow-Green $

• Fasten the power supply cable in the

corresponding cable clamp and close the cover.

Electrical Connection:

Voltage Frequency: 230

V-1+N 50Hz

Fuse Section: 16A

Supply cable:

3x1.5mm

2

You can connect your oven to the system means of

a terminal board. Refer to above information for the

minimal cable sections and the calibration of the

protective elements according to the connection.

If the appliance is installed with a junction box, an

omnipolar circuit breaker - with a minimum contact

opening of 3mm - should be installed between the

appliance and the mains.

Power cable supply connection to the electrical

mains:

We recommend you use a power supply cable which

is long enough to allow you to take the oven out of

its recess in the event of maintenance operations

(only use HAR - H 05 - RRF quality cables fitted with

a plug conforming to the regulations in force.
The plug must be accessible at all times.

Unplug the appliance before all operations, even

when replacing the oven lamp.

Using the appliance without correct earthing is

highly dangerous.

! After connecting the appliance to the flexible

cable, tighten all the screws on the terminal

board.

4

2

N

L

Electrical Connection