Elinca RX 600 User Manual
Page 9

8
23018
23101
23022
230V Modelling lamps and fuses
Unit
Modelling lamp
Code
Socket
Fuse
Code
Style 300RX
250W halostar
23018
E27
2,5AF 19033
Style 600RX
250W halostar
23018
E27
2,5AF 19033
Style 1200RX
300W halogen
23022
GX 6,35
2,5AF 19033
The touch pad (14) controls the modelling lamp on/off and the proportional light.
Select the power with the touch pad (15). The modelling light output (100%) is achieved when
the power value is set to maximum.
Proportional modelling lamp, is set when the position "PROP" is selected (led is illuminated), the
light output is proportional to the selected flash power.
For all types of Style RX compact flash units, use maximum 250 - 300W modelling lamps.
This lamp socket adapter E27 to GX 6.35 (code 23101) allows the use of the halogen lamp
300W, GX 6.35 (code 23022) for Style 300 and 600 RX units.
If the modelling lamp does not light up.
1. The filament is broken after long use (replace lamp and fuse)
2. The filament is broken after shock (replace lamp and fuse)
3. An internal component failure (return the unit to customer service)
Modelling Light
120V Modelling lamps and fuses
Unit
Modelling lamp
Code
Socket
Fuse
Code
Style 300RX
150W halogen
23037
BA15D
4 AF
19035
Style 600RX
150W halogen
23037
BA15D
4 AF
19035
Style 1200RX
250W halogen
23038
BA15D
4 AF
19035
120V «Canada Version» Modelling lamps and fuses
Unit
Modelling lamp
Code
Socket
Fuse
Code
Style 300RX
150W halogen
23012
E27
4 AF
19035
Style 600RX
150W halogen
23012
E27
4 AF
19035
Style 1200RX
150W halogen
23012
E27
4 AF
19035
230V Modelling lamp options:
120V Modelling lamp:
23037