The ENVIROGAS EG 28.FS.BV. will operate with no external power supply. These models have a Millivolt gas
control which uses the pilot flame to generate enough electricity to operate the main burner.

The appliance when installed, must be electrically connected and grounded in accordance with local codes or in
the absence of local codes, with the current CSA C22.1 CANADIAN ELECTRICAL CODE. Part 1, SAFETY
STANDARDS FOR ELECTRICAL INSTALLATIONS, or THE NATIONAL ELECTRICAL CODE ANSI / NFPA 70 in
the USA.

NOTE:
• Operation of the fan

increases the efficiency
and the heat output of the
appliance.

• The thermostat connects

to the two purple wires in
the harness

• Control panel light uses a

7w Max. bulb

WARNING:

ELECTRICAL

GROUNDING
INSTRUCTIONS.
This appliance is equipped
with a three-prong (grounding)
plug for your protection
against shock hazard and
should be plugged into a
properly grounded three-prong receptacle.

DO NOT

cut or remove the grounding prong from the plug.

INSTALLING REMOTE THERMOSTAT OR WALL SWITCH

RECOMMENDED WIRE SIZE

for thermostat installation: 18 gauge, 2 wire solid core, Low Voltage wire. (Bell wire)

1.

Install the 18 Gauge wire supplied to the two terminals on the thermostat or remote wall switch.

2.

Connect the other end of the wire to the gas valve using the two outside terminals on the front of the gas valve.
Use the terminals marked (TP/TH and TH).

RECOMMENDED MAXIMUM LEAD LENGTH (TWO WIRE)

WHEN USING WALL THERMOSTAT

WIRE SIZE MAXIMUM

LENGTH

14 GAUGE

100 FEET

16 GAUGE

64 FEET

18 GAUGE

40 FEET

20 GAUGE

18 FEET

CAUTION

Label all wires

prior to

disconnection

when servicing

controls. Wiring

errors can cause

improper and

dangerous

operation. Verify

proper operation

after servicing.