beautypg.com

Figure o-1. oven schematic-off condition – Electrolux E30MO75HP User Manual

Page 10

background image

Publication No: 5995535084

E30MO75HP / E30MO75HS

03/09 10

WIRING SCHEMATIC

Figure O-2. Oven Schematic-Microwave Cooking Condition

SCHEMATIC

NOTE: CONDITION OF OVEN
1.

DOOR CLOSED.

2.

COOKING TIME PROGRAMMED.

3.

“START” PAD TOUCHED.

SCHEMATIC

NOTE: CONDITION OF OVEN
1.

DOOR CLOSED.

2.

CLOCK APPEARS ON DISPLAY.

Figure O-1. Oven Schematic-OFF Condition

A1

A3

A7

A9

L.V.

TRANSFORMER

CONTROL

UNIT

SWITCH

3RD

DOOR

DM

FM

OL

CM

TURNT

ABLE MOT

OR

CONVECTION MOT

OR

TTM

OVEN LAMP

F

AN MOT

OR

DAMPER MOT

OR

PNK

PPL

BRN

ORG

*

RED

EPNK

MONIT

OR SWITCH

FUSE 20A

60Hz

120V

0.0033

"

F

AC125V

0.0033

"

F

AC125V

0.22

"

F

AC250V

NOISE FILTER UNIT

NOISE SUPPRESSION COIL

OVEN

MAGNETRON

CUT-OUT

THERMAL

THERMAL

CUT-OUT

CUT-OUT

THERMAL

CONV.

SCHEMATIC DIAGRAM (DOOR CLOSED,COOK OFF CONDITION)

SECONDARY

PRIMAR

Y

INTERLOCK SWITCH

(RY1)

MAGNETRON

(RY2)

INTERLOCK

RELAY

RY2

RY3

RY4

RY5

RY6

RY1

A5

(RY1)

0.94 "

TRANSFORMER

POWER

CAPACITOR

DAMPER

SWITCH

THER-

MISTOR

E1

E2

E3

E4

E5

F3

AH SENSOR

F2

F1

DOOR

SENSING

SWITCH

WIRE COLOR CODES ARE APPLICABLE TO PRIMARY CIRCUIT ONLY AND NOT
APPLICABLE TO LOW VOLTAGE CIRCUIT AND SECONDARY CIRCUIT.

NOTE: 1.

2.

*3.

H.V.

RECTIFIER

E6

ELEMENT

HEA

TING

HOT WIRE(S) MUST BE CONNECTED TO THE TERMINAL WITH BLUE MARK
ON THE LAMP SOCKET AND "H" MARK ON THE POWER SUPPLY CORD.

CIRCUITS SUBJECT TO CHANGE WITHOUT NOTICE

(RY3)

(RY3)

(RY2)

B5

B6

B4

B3

B2

B1

B8

B10

A1

A3

A7

A9

L.V.

TRANSFORMER

CONTROL

UNIT

SWITCH

3RD

DOOR

DM

FM

OL

CM

TURNT

ABLE MOT

OR

CONVECTION MOT

OR

TTM

OVEN LAMP

F

AN MOT

OR

DAMPER MOT

OR

PNK

PPL

BRN

ORG

*

RED

EPNK

MONIT

OR SWITCH

FUSE 20A

60Hz

120V

0.0033

"

F

AC125V

0.0033

"

F

AC125V

0.22

"

F

AC250V

NOISE FILTER UNIT

NOISE SUPPRESSION COIL

OVEN

MAGNETRON

CUT-OUT

THERMAL

THERMAL

CUT-OUT

CUT-OUT

THERMAL

CONV.

SECONDARY

PRIMAR

Y

INTERLOCK SWITCH

(RY1)

MAGNETRON

(RY2)

INTERLOCK

RELAY

RY2

RY3

RY4

RY5

RY6

RY1

A5

(RY1)

0.94 "

TRANSFORMER

POWER

CAPACITOR

DAMPER

SWITCH

THER-

MISTOR

E1

E2

E3

E4

E5

F3

AH SENSOR

F2

F1

DOOR

SENSING

SWITCH

WIRE COLOR CODES ARE APPLICABLE TO PRIMARY CIRCUIT ONLY AND NOT
APPLICABLE TO LOW VOLTAGE CIRCUIT AND SECONDARY CIRCUIT.

NOTE: 1.

2.

*3.

H.V.

RECTIFIER

E6

ELEMENT

HEA

TING

HOT WIRE(S) MUST BE CONNECTED TO THE TERMINAL WITH BLUE MARK
ON THE LAMP SOCKET AND "H" MARK ON THE POWER SUPPLY CORD.

CIRCUITS SUBJECT TO CHANGE WITHOUT NOTICE

(RY3)

(RY3)

(RY2)

B5

B6

B4

B3

B2

B1

B8

B10