beautypg.com

Vent safety shutoff system, Thermostat operation, Reversible vertical or horizontal draft diverter – Empire Products RH-50-6 User Manual

Page 8

background image

12822-3-0406

Page 8

VENT SAFETY SHUTOFF SYSTEM

This heater must be properly connected to a venting system. This

heater is equipped with a vent safety shutoff system.

This appliance needs fresh air for safe operation and must be

installed so there are provisions for adequate combustion and

ventilation air.

This room heater is equipped with a vent safety switch. The vent

safety switch will cause gas flow to the pilot to “shut off” due to

improper venting or a blocked flue.
If the vent safety switch continues to “shut off” the gas flow to

the pilot, a qualified service person must be contacted to inspect

for improper venting, blockage in the vent pipe or the vent safety

switch for being defective.

Warning:

Operation of this heater, when not connected to a

properly installed and maintained venting system or

tampering with the vent safety shutoff system, can result in

carbon monoxide (CO) poisoning and possible death.

REVERSIBLE VERTICAL OR HORIZONTAL DRAFT DIVERTER

This room heater has a reversible draft diverter. The draft diverter

is installed in the vertical position at the factory. Please use the

following steps to change the draft diverter from the vertical

positing to the horizontal position.

1. Remove L280 vent safety switch from the draft diverter.

2. Inside your yellow instruction envelope will be a 1 1/2” x 2

1/4” (38mm x 51mm) vent safety switch hole cover plate and

two (2) 1/2” screws for attachment of vent safety switch hole

cover plate to the draft diverter. Attach vent safety switch hole

cover plate over hole on the draft diverter from which the L280

vent safety switch was removed.

3. Remove two (2) screws at bottom of draft diverter and lift

upward to remove draft diverter from the draft diverter plate.

Rotate draft diverter into the horizontal position and slide back

into the draft diverter plate. Attach two (2) screws into bottom

of the drafter diverter.

4. Remove vent safety switch hole knockout and two (2) knockouts

for screws on opposite side of draft diverter.

5. Attach L280 vent safety switch to the draft diverter.

6. Repositioning of the draft diverter is completed.

DRAFT DIVERTER CAN BE EITHER A VERTICAL VENT

OR HORIZONTAL VENT

Figure 4

THERMOSTAT OPERATION

To turn on burner, rotate dial knob toward setting number 7. To

shut down burner, rotate dial knob toward setting number 1.
The dial numbers 1 to 7 correspond to 50

o

to 90

o

F (10

o

to 32

o

C).

This temperature at the bulb thermostat, not the room tempera-

ture. The owner is advised to determine the particular heat setting

that is desired for comfort, as heating requirements are different

for every owner.

Attention: If no heat is desired, turn the gas control knob to the

PILOT position.