beautypg.com

Technical data – Electrolux CSG 404 User Manual

Page 34

background image

TECHNICAL DATA

DIMENSIONS

Height

Width

Depth

Height to hotplate

900mm (nominal)

550mm (nominal)

600mm
(to front of
door panel)

Space for fixing at hotplate level

2mm minimum clearance

Space for fixing above hotplate level

Flush-see important note 'Location of Appliance' page 36.

Minimum space above hotplate

787mm (If a cooker hood is fitted refer to the cooker hood
installation instructions).

Weight of appliance

62.0kg.

Minimum distance from rear wall

5mm (spacer given by pressed spacer on vent panel).

CONNECTIONS

Gas

Rear left hand side of appliance at hotplate level.
Rc½ (½" B.S.P. female).

Electric

None

GRILL

Natural Gas

L.P.Gas

Heat Input

2.7kW (9215 Btu/h)

2.45kW (176 g/h)

Injector Marking

121

078

HOTPLATE

Natural Gas

R.H.F.

R.H.R.

L.H.R. L.H.F

Heat Input

1.0kW

1.9kW

1.9kW 2.9kW

(3412 Btu/h) (6483 Btu/h) (6483 Btu/h) (9895 Btu/h)

Injector Marking

070

096

096

119

L.P.Gas

R.H.F.

R.H.R.

L.H.R.

L.H.F.

Heat Input

1.0kW

1.9kW

1.9kW

2.8kW

(71.85 g/h)

(136.5 g/h)

(136.5 g/h)

(194 g/h)

Injector Marking

050

071

071 086

34