Powersure, Liebert corporation, Specifications – Emerson PowerSure PSA350MT-120 User Manual
Page 2: Runtime table

Liebert Corporation
1050 Dearborn Drive
P.O. Box 29186
Columbus, Ohio 43229
800 877 9222 Phone (U.S. &
Canada Only)
614 888 0246 Phone (Outside U.S.)
614 841 6022 FAX
Via Leonardo Da Vinci 8
Zona Industriale Tognana
35028 Piove Di Sacco (PD)
Italy
39 049 9719 111 Phone
39 049 5841 257 FAX
Emerson Network Power Asia Pacific
7/F., Dah Sing Financial Centre
108 Gloucester Rd, Wanchai
Hong Kong
852 25722201 Phone
852 28029250 FAX
liebert.com
24 x 7 Tech Support
800 222 5877 Phone
614 841 6755 (outside U.S.)
While every precaution has been taken to ensure accuracy
and completeness in this literature, Liebert Corporation assumes
no responsibility, and disclaims all liability for damages resulting
from use of this information or for any errors or omissions.
© 2005 Liebert Corporation. All rights reserved throughout
the world. Specifications subject to change without notice.
All names referred to are trademarks or registered
trademarks of their respective owners.
® Liebert and the Liebert logo are registered trademarks
of the Liebert Corporation.
SL-23272 (R2/06) Printed in USA
Emerson Network Power.
The global leader in enabling
business-critical continuity.
AC Power Systems
Connectivity
DC Power Systems
Embedded Power
Power Protection
Integrated Cabinet Solutions
Outside Plant
Precision Cooling
Site Monitoring and Services
Emerson Network Power and the Emerson
Network Power logo are trademarks and
service marks of Emerson Electric Co.
©2005 Emerson Electric Co.
The PSA receptacles are
spaced to accommodate
transformer blocks.
PowerSure
®
PSA
Specifications
M
odel Number
PSA350MT-120
PSA500MT-120
PSA650MT-120
PSA1000MT-120
POWER RATING VA/W
350VA /210 W
500 VA/ 300 W
650VA / 390 W
1000 / 600
DIMENSIONS: in. (mm)
Unit
4.6 x 7.7 x 8.7
4.6 x 7.7 x 8.7
4.6 x 14.1 x 8.7
4.6 x 14.1 x 8.7
W x D x H
(116x196x222)
(116x196x222)
(116x358x222)
(116x358x222)
WEIGHT: lbs (kg)
Unit
16.8 (7.6)
17.2 (7.8)
20.7 (9.4)
29.7 (13.5)
INPUT AC PARAMETERS
Surge Protection
570 J
Voltage Range Without
Battery Operation
78 VAC - 150 VAC, DIP switch selectable
Input Power Cord
6 ft. (1.8m) attached, w/NEMA 5-15 P
OUTPUT AC PARAMETERS
Output Receptacles
(4) NEMA
(4) NEMA
(4) NEMA
(6) NEMA
5-15R (orange)
5-15R (orange)
5-15R (orange)
5-15R (orange)
Battery backup
Battery backup
Battery backup
Battery backup
+ surge protection
+ surge protection
+ surge protection
+ surge protection
(2) NEMA
(2) NEMA
(2) NEMA
(2) NEMA
5-15R (black)
5-15R (black)
5-15R (black)
5-15R (black)
Surge protection
Surge protection
Surge protection
Surge protection
Voltage (Battery mode)
120VAC ±8%
Waveform (Battery mode)
Stepped Sinewave
Frequency
50 Hz or 60 Hz; auto sensing
PowerSure
®
PSA
Runtime Table
Typical Battery Backup Time
350VA
500VA
650VA
1000VA
Pentium II w/15” Monitor
33min
45 min
45 min
69 min
Pentium II w/17” Monitor
20 min
28 min
28 min
49 min
Pentium II w/21” Monitor
19 min
26 min
26 min
47 min
Pentium III w/15” Monitor
15 min
23 min
23 min
39 min
Pentium III w/17” Monitor
14 min
19 min
19 min
37 min
Pentium III w/21” Monitor
9 min
17 min
17 min
26 min
Pentium 4 w/15” Monitor
10 min
18 min
18 min
27 min
Pentium 4 w/17” Monitor
8 min
15 min
15 min
25 min
Pentium 4 w/21” Monitor
–
12 min
12 min
24 min
User replaceable batteries
ensure long product life.
6 ft. Power Cord
for easy access
Site Wiring Fault
Indicator
USB Port
DB-9 Port
(serial/contact closure)
Voltage Selector
Switches
Data-Line Protection
(Phone/Fax/Modem/
DSL/Internet)
Orange Output
Receptacles offer
Battery Backup and
Surge Protection
Black Output
Receptacles offer
Surge Protection
650 VA Model Shown
EmersonNetworkPower.com