Room ventilation – Location and venting.

ATTENTION: An exhaust fan may be used with the appliance; in each case it shall be installed in
conformity with the national standards in force.
ATTENTION: Exhaust hood operation may affect other vented appliances; in each case it shall be
installed in conformity with the national standards in force.

Conversion to different types of gas

Before carrying out any maintenance work, disconnect the appliance from the gas and electric
supply. For Natural Gas fit regulator assembly described in Fig. 5. For LP Gas fit assembly described
in fig. 5.

- CHANGING THE NOZZLES FOR USE WITH OTHER TYPES OF GAS:

To change the nozzles of the burners use the following procedure:

Lift up the burners and unscrew the nozzles ( Fig. 8) using an adjustable spanner of 7 mm and change the
nozzles with those designed for the new gas supply according to the information given in TABLE A shown
below.

TABLE A: Adapting to different types of gas
Drop-in cooktop with 5 workyop burners model B3H0..(A or Q)7X(2 or 5)D

Burner

Position

Inj. size

Gas

Pressure

Max Rate

Min Rate

By-pass size

1/100mm

Type

[i.w.c.]

[BTU/h]

[W]

[BTU/h]

[W]

[1/100mm]

Auxiliary

Front R

92

NG

4”

3750

1098

900

264

Regulated

56

LP(Propane)

11”

3750

1098

900

264

29

Semi-Rapid

Rear L

117

NG

4”

6000

1759

1500

439

Regulated

Rear R

73

LP(Propane)

11”

6300

1845

1500

439

36

Rapid

Front L

155

NG

4”

10400

2046

2500

732

Regulated

98

LP(Propane)

11”

11400

3339

2500

732

47

Centre Inner

80

NG

4”

900

264

Regulated

Dual

50

LP(Propane)

11”

NG 17000

4980

29

burner

Centre Outer

N°2 x 130

NG

4”

LP 18800

5507

Regulated

N°2 x 83

LP(Propane)

11”

65

Drop-in cooktop with 6 workyop burners model B3K0..(Q or U)7X(2 or 5)

Burner

Position

Inj. size

Gas

Pressure

Max Rate

Min Rate

By-pass size

1/100mm

Type

[i.w.c.]

[BTU/h]

[W]

[BTU/h]

[W]

[1/100mm]

Auxiliary

Front R

0,92

NG

4”

3750

1098

900

264

Regulated

0,56

LP(Propane)

11”

3750

1098

900

264

29

Semi-Rapid

Rear L & C

1,17

NG

4”

6000

1759

1500

429

Regulated

Front C

0,73

LP(Propane)

11”

6300

1845

1500

439

36

Rapid

Rear R

1,55

NG

4”

10400

2046

2500

732

Regulated

0,98

LP(Propane)

11”

11400

3339

2500

732

47

Centre Inner

0,80

NG

4”

900

264

Regulated

Dual

0,50

LP(Propane)

11”

NG 17000

4980

29

burner

Centre Outer

N°2 x 1,30

NG

4”

LP 18800

5507

Regulated

N°2 x 0,83

LP(Propane)

11”

65

CAUTION: save the orifices removed from the appliance for future use

Regulation of burners

Regulation of the "MINIMUM" on the burners

To regulate the minimum on the burners carry out the following procedure indicated below:
1) Turn on the burner and put the knob onto position MINIMUM ( small flame ).
2) Remove the knob ( Fig. 9) of the tap which is set for standard pressure. The knob is found on the bar of
the tap itself.
3) Beside the tap bar on the work top, use a small screwdriver that fits the screw (gold) found on the lower
part of the tap (auxiliary, semirapid, rapid Fig. 9) (dual fig.10) and turn the fixing screw to the right or left until
the flame of the burner is regulated in the most suitable way to MINIMUM.
4) Make sure that that the flame does not go out when changing the position quickly from MAXIMUM to the
MINIMUM position.

ATTENTION: The regulation described above can be carried out only with burners using natural gas,
while with burners using propane gas the screw must be fully screwed in, in a clockwise direction.

Adaptation of the pressure regulator for use with different type of gas

The pressure regulator supplied with the appliance is a convertible type pressure regulator for use with
Natural Gas at a nominal outlet pressure of 4” w.c. or LP gas at a nominal outlet pressure of 11” w.c. and it is
pre-arranged from the factory to operate with one of these gas/pressure as indicated in the pre-arranging
labels affixed on the appliance, package and Instruction booklet.