Room ventilation – Location and venting.
ATTENTION: An exhaust fan may be used with the appliance; in each case it shall be installed in
conformity with the national standards in force.
ATTENTION: Exhaust hood operation may affect other vented appliances; in each case it shall be
installed in conformity with the national standards in force.
Conversion to different types of gas
Before carrying out any maintenance work, disconnect the appliance from the gas and electric
supply. For Natural Gas fit regulator assembly described in Fig. 5. For LP Gas fit assembly described
in fig. 5.
- CHANGING THE NOZZLES FOR USE WITH OTHER TYPES OF GAS:
To change the nozzles of the burners use the following procedure:
Lift up the burners and unscrew the nozzles ( Fig. 8) using an adjustable spanner of 7 mm and change the
nozzles with those designed for the new gas supply according to the information given in TABLE A shown
below.
TABLE A: Adapting to different types of gas
Drop-in cooktop with 5 workyop burners model B3H0..(A or Q)7X(2 or 5)D
Burner
Position
Inj. size
Gas
Pressure
Max Rate
Min Rate
By-pass size
1/100mm
Type
[i.w.c.]
[BTU/h]
[W]
[BTU/h]
[W]
[1/100mm]
Auxiliary
Front R
92
NG
4”
3750
1098
900
264
Regulated
56
LP(Propane)
11”
3750
1098
900
264
29
Semi-Rapid
Rear L
117
NG
4”
6000
1759
1500
439
Regulated
Rear R
73
LP(Propane)
11”
6300
1845
1500
439
36
Rapid
Front L
155
NG
4”
10400
2046
2500
732
Regulated
98
LP(Propane)
11”
11400
3339
2500
732
47
Centre Inner
80
NG
4”
900
264
Regulated
Dual
50
LP(Propane)
11”
NG 17000
4980
29
burner
Centre Outer
N°2 x 130
NG
4”
LP 18800
5507
Regulated
N°2 x 83
LP(Propane)
11”
65
Drop-in cooktop with 6 workyop burners model B3K0..(Q or U)7X(2 or 5)
Burner
Position
Inj. size
Gas
Pressure
Max Rate
Min Rate
By-pass size
1/100mm
Type
[i.w.c.]
[BTU/h]
[W]
[BTU/h]
[W]
[1/100mm]
Auxiliary
Front R
0,92
NG
4”
3750
1098
900
264
Regulated
0,56
LP(Propane)
11”
3750
1098
900
264
29
Semi-Rapid
Rear L & C
1,17
NG
4”
6000
1759
1500
429
Regulated
Front C
0,73
LP(Propane)
11”
6300
1845
1500
439
36
Rapid
Rear R
1,55
NG
4”
10400
2046
2500
732
Regulated
0,98
LP(Propane)
11”
11400
3339
2500
732
47
Centre Inner
0,80
NG
4”
900
264
Regulated
Dual
0,50
LP(Propane)
11”
NG 17000
4980
29
burner
Centre Outer
N°2 x 1,30
NG
4”
LP 18800
5507
Regulated
N°2 x 0,83
LP(Propane)
11”
65
CAUTION: save the orifices removed from the appliance for future use
Regulation of burners
Regulation of the "MINIMUM" on the burners
To regulate the minimum on the burners carry out the following procedure indicated below:
1) Turn on the burner and put the knob onto position MINIMUM ( small flame ).
2) Remove the knob ( Fig. 9) of the tap which is set for standard pressure. The knob is found on the bar of
the tap itself.
3) Beside the tap bar on the work top, use a small screwdriver that fits the screw (gold) found on the lower
part of the tap (auxiliary, semirapid, rapid Fig. 9) (dual fig.10) and turn the fixing screw to the right or left until
the flame of the burner is regulated in the most suitable way to MINIMUM.
4) Make sure that that the flame does not go out when changing the position quickly from MAXIMUM to the
MINIMUM position.
ATTENTION: The regulation described above can be carried out only with burners using natural gas,
while with burners using propane gas the screw must be fully screwed in, in a clockwise direction.
Adaptation of the pressure regulator for use with different type of gas
The pressure regulator supplied with the appliance is a convertible type pressure regulator for use with
Natural Gas at a nominal outlet pressure of 4” w.c. or LP gas at a nominal outlet pressure of 11” w.c. and it is
pre-arranged from the factory to operate with one of these gas/pressure as indicated in the pre-arranging
labels affixed on the appliance, package and Instruction booklet.