beautypg.com

Make electrical connection, Warning – JennAir Custom Series 15 Inch Induction Wok Installation Instructions User Manual

Page 8

background image

8

4. Start the hold-down screws into the hold-down brackets.

5. Center the cooktop in the opening and, using a wood block

between the screw and the countertop, moderately tighten

the screws to secure cooktop.
IMPORTANT: Do not tighten screws directly against the

countertop.

Make Electrical Connection

This cooktop is manufactured with a frame-connected green or

bare ground wire. Connect the cooktop cable to the junction box

through the UL Listed or CSA Approved conduit connector.

Electrical Connection Options

If Your Home Has: And You Will Be

Connecting to:

Go to Section:

4-wire direct

A fused disconnect

or circuit breaker

box

4-Wire Cable from

Power Supply to

3-Wire Cable from

Cooktop

(12.7 cm)

5"

3-wire direct

A fused disconnect

or circuit breaker

box

3-Wire Cable from

Power Supply to

3-Wire Cable from

Cooktop

(8.9 cm)

3

¹⁄₂

"

4-Wire Cable from Power Supply to 3-Wire Cable

from Cooktop

IMPORTANT: Use the 3-wire cable from power supply where

local codes do not permit connecting the frame-ground

conductor to the neutral (white) junction box wire.

1. Disconnect power.
2. Remove junction box cover, if present.
3. Connect the flexible cable conduit from the cooktop to the

junction box using a UL Listed or CSA Approved connector

for 1/2" (13 mm) conduit.

4. Tighten screws on conduit connector if present.
5. Connect the two black wires together using the UL Listed

wire connectors.

6. Connect the two red wires together using the UL Listed

wire connectors.

7. Connect the white wire using the UL Listed wire connectors.
8. Connect the green or bare ground wire from the cooktop

cable to the green or bare ground wire (in the junction box)

using the UL Listed wire connectors.

9. Install junction box cover.
10. Reconnect power.

A

B

C

E

D

A. Countertop
B. Wood block
C. Hold-down screw
D. Hold-down bracket
E. Burner box

WARNING

Electrical Shock Hazard

Disconnect power before servicing.
Use 8 gauge copper wire.
Electrically ground cooktop.
Failure to follow these instructions can result in death,

fire, or electrical shock.

G

F

H

A

E

B

D

C

A. 4-wire cable from power supply
B. Black wires
C. White wires
D. Bare or green wires
E. 3-wire cable from cooktop

F. Junction box
G. Red wires
H. UL Listed or CSA Approved

conduit connector

This manual is related to the following products: