Gas Connection

Connect a manual shut-off valve to the gas supply in an accessible location for turning on or
shutting off gas to the appliance.


• Leak testing of the appliance shall be conducted by the installer according to the instructions

given.

• Issues arising from a failure to do so will not be covered by warranty.
• Do not install the pressure regulator backwards as the gas will not flow correctly. Check that the

arrow on the back points in the direction of gas flow.

• Parts required for connection from gas supply to regulator are the responsibility of the

installer/owner.

• To reduce the likelihood of gas leaks, apply Teflon tape or a thread compound approved for use

with Propane or Natural gases to all threaded connections. Apply a non-corrosive leak detection
fluid to all joints and fittings in the gas connection between the supply line shut-off valve and the
cooktop inlet.

• Check for leaks. Bubbles appearing around fittings and connections will indicate a leak. If a leak

appears, turn off supply line gas shut-off valve, tighten connections, turn on the supply line gas
shutoff valve, and retest for leaks. Never test for gas leaks with an open flame.

WARNING

A qualifies service person or gas appliance installer must make the gas supply connection.

Pressure Test Method

• Remove grate and burner cap
• Remove aluminum gas spreader
• Temporarily remove the injectors
• Connect the pressure Test instrument into injector holder
thread zone (M6x0,75)
• Check if the cooktop has the correct pressure
• Fix the injector removed for testing and replace the parts in the right position.