EXHAUST VENT (season)
This vent should be cleaned every year or after two (2) tons of pellets. We recommend contacting your

dealer for professional cleaning. To clean the vent pipe, tap lightly on the pipe to dislodge any loose ash.

Open the bottom of the “T” to dump the ash, then vacuum as much of the ash out of the vent pipe as

possible.

BLOWER MECHANISMS (season)
Unplug the stove then open the right and left side panels to access the two blowers. Vacuum all dust

from motors. DO NOT lubricate the motors. Check gaskets and replace if needed.

ALL HINGES (season)
Check all the hinges on the unit to ensure proper movement.

POST SEASON CLEAN-UP
Once you are finished using the pellet appliance for the season, unplug the stove for added electrical

protection. It is very important that the stove be cleaned and serviced as stated above.

CLEANING SURFACES
Enamel finishes and painted surfaces can be wiped down with a soft damp cloth. The paint on the firebox

panels may discolour or peel. This is due to extreme conditions applied to the paint and is in no way

covered by warranty.

FIREBOX PANEL
All surfaces should be brushed off periodically.

REPLACING DOOR GLASS
It is recommended that your ENVIRO dealer replace the glass if broken.
The door glass is made of high temperature PYRO CERAMIC 5 mm thick. The center panel is 18.5 x 13.5

inches (46.99 cm x 34.29 cm) and must be replaced with (PART # 20-023). Substitute materials will not

be permitted.