Installation requirements electrical connection – Bertazzoni Master Series 36 Inch Freestanding Induction Range Installation Instructions User Manual

Page 9

background image

9

/ Installation requirements / Electrical connection

ELECTRICAL

A properly-grounded horizontally- mounted electri-
cal receptacle should be installed no higher than
3” (7.6 cm) above the

fl

oor, no less than 2” (5 cm)

and no more than 8” (20,3 cm) from the left side
(facing product).
Check all local code requirements.

.

Warning!

ELECTRICAL SHOCK HAZARD
Disconnect electrical power at the circuit bre-
aker box or fuse box before installing the ap-
pliance.
Provide appropriate ground for the appliance.
Use copper conductors only.
Failure to follow these instructions could re-
sult in serious injury or death.

Electrical grounding

This appliance is equipped with a four-prong plug
for your protection against shock hazard and
should be plugged directly into a properly groun-
ded socket. Do not cut or remove the grounding
prong from this plug.

Caution

Label all wires prior to disconnecting when
servicing controls. Wiring errors can cause
improper and dangerous operation.
Verify proper operation after servicing.

The appliance shall be connected to a single pha-
se electric line rated at 120/208Vac or 120/240Vac
and 60Hz frequency.

Install a suitable electric power supply receptacle
connection type NEMA 14-50R able to support a
load of at least 30 A (per line) according to local
code requirements. For four or three wires power
supply connection system see diagram below.

INSTALLATION REQUIREMENTS

ELECTRICAL CONNECTION

installation area for the connection

Type

Voltage

Circuit rating

Electrical
supply

30” IND-
DFM

120/208V
120/240V

10300W 46A
11000W 48A

40A
40A

30” IND-
DFS

120/208V
120/240V

11700W 53A
13000W 56A

40A
40A

36” IND-
DFM

120/208V
120/240V

14000W 62A
14800W 64A

40A
40A

36” IND-
DFS

120/208V
120/240V

15600W 70,5A
17000W 73,5A

50A
50A