Connecting gas dryers, Ductwork, Routing and connecting ductwork – LG 27 Inch Electric Smart Dryer Owners Guide User Manual

Page 20: Electrical requirements for gas models

background image

20

INSTALLATION

Ductwork

NOTE

• Deduct 6 ft. (1.8 m) for each additional elbow. Do

not use more than four 90° elbows.

• In Canada, only those foil-type flexible ducts, if

any, specifically identified for use with the

appliance by the manufacturer should be used.

In the United States, only those foil-type flexible

ducts, if any, specifically identified for use with

the appliance by the manufacturer and that

comply with the Outline for Clothes Dryer

Transition Duct, Subject 2158A, should be used.

Routing and Connecting Ductwork

Follow the guidelines below to maximize drying

performance and reduce lint buildup and

condensation in the ductwork. Ductwork and

fittings are NOT included and must be purchased

separately.
• Use 4-inch (10.2 cm) diameter rigid, semi-rigid or

flexible metal ductwork.

• The exhaust duct run should be as short as

possible.

• Use as few elbow joints as possible.
• The male end of each section of exhaust duct

must point away from the dryer.

• Use duct tape on all duct joints.
• Insulate ductwork that runs through unheated

areas in order to reduce condensation and lint

buildup on duct surfaces.

• Incorrect or inadequate exhaust systems are not

covered by the dryer warranty. Dryer failures or

service required because of such exhaust

systems will not be covered by the dryer

warranty.

Correct Venting

Incorrect Venting

Connecting Gas Dryers

WARNING

• To reduce the risk of fire or explosion, electric

shock, property damage, injury to persons, or

death when using this appliance, follow

requirements including the following:

Electrical Requirements for Gas

Models

WARNING

• This dryer is equipped with a three-prong

grounding plug for protection against shock

hazard which should be plugged directly into a

properly grounded three-prong receptacle. Do

not cut or remove the grounding prong from

this plug.

• Do not, under any circumstances, cut or remove

the third (ground) prong from the power cord.

• For personal safety, this dryer must be properly

grounded.

Wall Cap Type

No. of

90°

Elbows

Maximum length

of 4-inch

diameter rigid

metal duct

Recommended

0

65 ft. (19.8 m)

1

55 ft. (16.8 m)

2

47 ft. (14.3 m)

3

36 ft. (11.0 m)

4

28 ft. (8.5 m)

Use for only

short run

installations

0

55 ft. (16.8 m)

1

47 ft. (14.3 m)

2

41 ft. (12.5 m)

3

30 ft. (9.1 m)

4

22 ft. (6.7 m)

a

a

a: 4 ‘’ (10.2 cm)

b: 2.5 ‘’ (6.35 cm)

b