Sr-30 clearances wall mount installation – Empire Comfort Systems SR-18-3 User Manual
Page 10
16942-3-0506
Page 10
When facing the front of the appliance the following
minimum clearances to combustible construction must be
maintained.
Left side 8 inches (203mm). Right side 8 inches
(203mm).
Do not install in alcove or closet.
Rear wall 0 inches (0mm). Ceiling 36 inches (914mm).
Minimum vertical clearance from a projection above
the appliance (shelves, window sills, etc.) 36 inches
(914mm).
Floor (top surface of carpeting, tile, etc.) 2 inches
(51mm).
Provide adequate clearances around air openings.
Adequate accessibility clearances for purposes of servicing
and proper operation must be provided.
Refer to Figures 9, 10, 11 and 12 for measurements in order to locate (4) mounting holes on wall. Figures 9, 10, 11 and 12 are the front
views of the heaters.
1. Remove lower louver from casing assembly (2 screws).
2. Remove reflector from casing assembly (2 screws).
3. Remove upper louver from casing assembly (2 screws).
SR-30 CLEARANCES
WALL MOUNT INSTALLATION