Completion & storage – Earlex SS200 User Manual
Page 5

5
COMPLETION & STORAGE
1.	 Switch	off	steam	and	vacuum	pump	switches,	and	unplug	the	unit.	
2.	 Allow	the	unit	to	cool	completely	and	then	empty	the	unit	and	waste	water	collection	tank	of	any	remaining	water.	Never	leave	
water in the unit whilst being stored.
3. Once the unit has cooled, wind the cable around the base of the feet on the unit and then wind the hose around the leg clips.
Slot the steam plate into the side slots on the feet.
HOW TO ASSEMBLE THE SPARE VACUUM CUP
AND STEAM PLATE FILTER
Insert the vacuum seal (6) into the steam plate as shown.
Insert the foam pump filter (7) as shown.
1.1
1.2
1.3
1.4
1.5
2.1
2.2
2.3
2.4
CEILINGS
Please note: While using the steam plate on the ceiling the unit will expel a small amount of water out of the base of the
unit from the vacuum pump exhaust hose onto the surface below. Ensure that all floor surfaces are protected by dust
sheets or plastic.
Please ensure that the hose is unclipped from the steam plate handle when working on the ceiling,
as shown. This will enable the hose to hang vertically and make sure the steam plate remains in
position.
1. If you are right handed, hold the steam plate in your left hand and place flat against the ceiling where
you wish to commence removing the Artex
®
/paper.
2. Leave the plate on the ceiling for a maximum of 10 seconds. The length of time will depend on the type
of covering you are removing.
3.	 If	you	are	left	handed	you	may	find	it	easier	to	operate	with	the	other	hand.
4.	 Move	the	steam	plate	to	the	section	immediately	next	to	where	you	have	just	been	working	and	use	a	
wallscraper to remove the section that has just been steamed.
5. Empty the ceiling waste water tank when it starts to become full. It holds a total of 500ml of water and
in 78 minutes should only require emptying once if a full tank is used.
6. By working in this way you should be able to remove Artex
®
/paper continuously.
7.	 You	may	have	to	leave	the	plate	on	the	ceiling	for	longer	periods	or	re-steam	if	not	completely	removed.
8.	 Operate	the	steamer	until	steam	is	no	longer	produced	(there	is	a	safety	cut-out	when	water	level	gets	too	low),	switch	off	the	
vacuum and leave for a minimum of 2 minutes before refilling. Allow to cool completely before packing away.
3mm