About the exhaust feature.

GEAppliances.com

Charcoal Filter

The charcoal filter cannot be cleaned. It must

be replaced. Order Part No. WB02X10943 from

your GE supplier.

If the model is not vented to the outside, the

air will be recirculated through a disposable

charcoal filter that helps remove smoke and

odors.

The charcoal filter should be replaced when it is

noticeably dirty or discolored (usually after 6 to

12 months, depending on usage). See

Optional

Kits

, page 8, for more information.

To Remove the Charcoal Filter

To remove the charcoal filter

, first disconnect

power at the main fuse or circuit breaker, or pull

the plug.
To remove the top grille:

• open the microwave door

• remove 2 screws from the top

• slide the grille to the left and forward to

remove

You may need to open the cabinet doors to

remove the screws.

Slide the filter down and out.

To Install the Charcoal Filter

To install a new charcoal filter,

remove plastic

and other outer wrapping from the new filter.
Insert the top of the filter up and into the

grooves on the inside of the top opening. Push

the bottom of the filter in until it rests in place.

Replace the grille by aligning the tabs with the

cutouts on the frame and sliding the grille to the

right. Replace the grille screws.