Installing The Hanger

Ball/Downrod Assembly

(For Standard Mounting)

1. Pass the 56" motor leads through the opening in

the ceiling cover. Be sure the cover is oriented
correctly.

2. Separate, untwist and unkink the three motor

leads. Route the motor leads through the hanger
ball/downrod assembly.

3. Loosen the two setscrews in the motor coupling.

Align the clevis pin holes in the downrod with the
holes in the motor coupling. Install the clevis pin
and secure with the hairpin clip (Figure 1). The
clevis pin must go through the holes in the motor
coupling and the holes in the downrod. Be sure to
push the straight leg of the hairpin clip through the
hole near the end of the clevis pin until the curved
portion of the hairpin clip snaps around the clevis
pin. The hairpin clip must be properly installed to
prevent the clevis pin from working loose. Pull on
the hanger ball to make sure the clevis pin is
properly installed.

4. While pulling up on the hanger ball, securely

tighten the two setscrews in the motor coupling
(Figure 1).

NOTE: The setscrews must be properly installed
as described above, or fan wobble could result.

5.The fan comes with blue, black and white leads that

are 56” long. Measure up approximately
6 to 9-inches above top of hanger ball/downrod
assembly. Cut off excess leads and strip back
insulation 1/2-inch from end of leads.

4

HANGER
BALL/DOWNROD
ASSEMBLY

CEILING
COVER

SETSCREW

CLEVIS
PIN

HAIRPIN
CLIP

DECORATIVE
CAP

SETSCREW

MOTOR COUPLING

Figure 1

IMPORTANT

Your ceiling fan is designed to be installed
either in the standard manner, or in the
close-to-the-ceiling manner. Using the
standard method, the hanger ball/downrod
assembly will suspend the fan several inches
below the ceiling cover. Using the
close-to-the-ceiling method, the ceiling cover
installs directly on the fan motor housing,
thus mounting the fan 3-1/2 inches closer to
the ceiling than the standard method. In no
case should the fan blades be lower than
seven feet above the floor. Depending on
your desired mounting method, proceed to
“INSTALLING HANGER BALL/DOWNROD
ASSEMBLY” for standard mounting, or to
“INSTALLING CEILING COVER ON FAN
MOTOR HOUSING” for close-to-the-ceiling
mounting.

It is critical that the clevis pin in the motor coupling
is properly installed and the setscrews securely
tightened. Failure to verify that the pin and setscrews
are properly installed could result in the fan falling.

WARNING

!

Installing The Ceiling Cover

On The Fan Motor Housing

(For Close-to-the-Ceiling Mounting)

1. Remove and retain three screws from the top of

the motor housing (Figure 2A).

2. Position the rubber gasket (supplied in parts bag)

on the motor housing (small holes in gasket
centered over the screw holes in the housing)
(Figure 2B).

3. Gently pry the decorative cap (Figure 1) from the

ceiling cover. Align the holes in the ceiling cover
with the holes in the motor housing and secure
using the three screws (Figure 3).

4. The fan comes with blue, black and white leads

that are 56” long. Measure up approximately 6 to
9-inches above the motor coupling. Cut off excess
leads and strip back insulation 1/2-inch from ends
of leads.

REMOVE SCREWS (3)

INSTALL GASKET

Figure 2A

Figure 2B

SCREW (3)

RUBBER
GASKET