beautypg.com

Technical specifications, Motor thermostat, Trouble shooting guide – Euro-Pro BIG SHARK V1505 User Manual

Page 3

background image

OPERATING INSTRUCTIONS cont.

GETTING TO KNOW YOUR BIG SHARK

The post motor filter is a washable filter

but should be replaced every three (3)

months depending on usage.

• Disconnect from electrical outlet

before cleaning or changing the filter.

• Remove the exhaust cover from the

rear of the unit.

• Rinse the post motor filter in

lukewarm water and dry the filter

completely. Do not use a washing

machine to rinse the filter. Do not

use a hair dryer to dry it. Air dry only

for 24 hours. Never operate the

vacuum without the post motor filter

in place.

• A severely clogged filter should be

thoroughly washed with fresh tepid

water. A mild detergent can be used

if required.

IMPORTANT:

This unit is equipped

with a motor protective thermostat. If

for some reason the vacuum cleaner

should overheat, the thermostat will

automatically turn the unit off. Should

this occur:

• Push the On/Off button once.

• Disconnect the plug from the

power source.

• Check the source of overheating

problem. (i.e. clogged hose or

filter)

• If clogged hose or filter is found,

unclog the hose and replace the

filters.

• Wait at least 45 minutes before

attempting to reuse the vacuum.

• After unit has cooled down for

45 minutes, plug in the cleaner

and push the On/Off button. The

vacuum should start again.

• If the vacuum still does not start,

contact EURO-PRO at

1-800-798-7398.

Motor Thermostat

HEPA Filter

Debris Screen

8.

Dust Cup (Container)

9.

Flexible Hose

10. Oval Brush

11. Crevice Tool

12. Shoulder Strap

13. HEPA Dust Cup Filter

w/Debris Screen

1. Dust Cup Release Button

2. On/Off Power Switch

3. Intelli-Sense

TM

Filter Monitor

4. Handle

5. Shoulder Strap Attachment Points

6. Suction Hole

7. Exhaust Cover

TROUBLE SHOOTING GUIDE

PROBLEM

POSSIBLE REASON

POSSIBLE SOLUTION

HAND VACUUM

WILL NOT

OPERATE

1. Power cord not firmly plugged

into outlet.

2. No power in wall outlet.

3. Needs

servicing.

4. Thermostat

has

tripped.

1. Plug unit in firmly.

2. Check fuse or breaker.

Replace fuse/reset breaker.

3. Call

1-800-798-7398.

4. Turn the unit off and unplug

from outlet. Allow unit to cool

down; then restart.

HAND VACUUM

WILL NOT PICK-UP

OR SUCTION

POWER IS WEAK

1.

Dust cup is full.

2. Unit

clogged.

3. HEPA Dust Cup Filter needs

cleaning or replacing.

1. Empty and clean dust cup –

(see page 4).

2. Turn unit off and unplug

from wall outlet. Remove

HEPA Dust Cup Filter and

check for object(s) in air

duct and remove.

3. Clean or replace HEPA

Dust Cup Filter.

(see page 4)

DUST ESCAPING

FROM HAND

VACUUM

1.

Dust cup is full.

2. HEPA Dust Cup Filter is not

installed correctly.

3. There is a puncture/hole in

HEPA Dust Cup Filter.

1. Empty and clean dust cup.

(see page 4)

2. Review HEPA Dust Cup

Filter instructions.

(see page 4)

3. Replace HEPA dust cup

filter. (see page 4)

HAND VACUUM

HOSE OR

BRUSHES WILL

NOT PICK-UP

1. Hose

clogged.

2.

Dust cup is full.

1. Remove hose and/or

bushes. Remove obstruction

from hose.

2. Empty and clean dust cup.

5

Technical Specifications

Voltage:

120V., 60Hz.

Power:

7.5 Amps, 900 Watts

2