Clearances to combustibles - freestanding, Alcove clearances - freestanding, Installation – Enviro Meridian User Manual
Page 13

Minimum
6" (150mm)
This pellet stove requires floor protection. The floor protection must be non-combustible, extending beneath
the stove the full width and depth of the unit including 6“ (150 mm) in front for ember protection.
A
LCOVE
C
LEARANCES
- F
REESTANDING
:
Figure 10: Meridian on Floor
Protection.
Minimum Width
36" (914mm)
Minimum Height
48" (1219mm)
Maximum Depth
30" (762mm)
Back wall
S
id
e
w
al
l
Adjacent
wall
2"
(51mm)
3" (76mm)
6"
(152mm)
Installation
C
LEARANCES
TO
C
OMBUSTIBLES
- F
REESTANDING
:
These dimensions are minimum clearances but it is recommended that you ensure sufficient room for
serving, routine cleaning and maintenance.
Figure 11: Minimum Clearances to Combustibles for
Freestanding Meridian.
Figure 12: Alcove Clearances Freestanding Meridian.