Framing mount brackets, Corner installation, Raised fireplaces and hearths – Enviro C-10791 User Manual
Page 13: Initial installation
Mount the two framing mount brackets on each side and secure the fireplace
to framing with screws or nails (refer to Figure 7). The brackets will allow
for a 1⁄2” (13 mm), 5⁄8” (16 mm), 3⁄4” (19 mm) thick finishing wall. The wall
may be finished up to the fireplace facing with combustible material.
Figure 11. Nail Tab.
Initial Installation
QUALIFIED INSTALLERS ONLY
F
RAMING
M
OUNT
B
RACKETS
:
C
ORNER
I
NSTALLATION
:
The dimensions for installing a fireplace in the corner of a room are given in Figures 12 and 13. Refer to
“I
NITIAL
I
NSTALLATION
- V
ENT
C
ONFIGURATIONS
AND
R
ESTRICTOR
S
ETTINGS
” for allowable pipe lengths.
Do not interfere with the structural integrity of the walls.
Figure 12. Dimensions for a corner installation, rear
vented.
13
Figure 13. Dimensions for a corner installation, top
vented.
R
AISED
F
IREPLACES
AND
H
EARTHS
:
Figure 15. Raised Fireplace with Floor Level Hearth
Figure 14. Raised Fireplace with Raised Hearth