INSTRUCTIONS FOR THE INSTALLER

Safety Advice


This cooker must be installed in accordance
with the IEE Wiring Regulations (Current
Edition).
Detailed recommendations are contained in the
following British Standards Codes Of Practice:
B.S. 6172/ B.S. 5440, Par. 2 and B.S. 6891
Current Editions.

Location

This cooker has been registered as a "Class X"
appliance according to Fire Risk Regulations.
Any adjacent cabinets or walls must not exceed
the cooker's height.
The cooker may be located in a kitchen, a
kitchen/diner or bed sitting room, but not in



a bathroom or shower room.
The minimum distance combustible material can
be fitted above the cooker in line with the edges
of the cooker is 420 mm. If it is fitted below 420
mm. a space of 50 mm. must be allowed from
the edges of
the cooker.
The minimum distance combustible material can
be fitted directly above the cooker is 700 mm.

The adjacent furniture panels have to be
heat proof or protected by such material.








TECHNICAL DATA

Dimensions



Height

Depth
Width
Oven Capacity

Hob

Front left heating plate
(rapid)
Back left heating plate
(normal)
Back right heating plate
(normal) Front right
heating plate (normal)
Total Rating





900mm
500mm
600mm

1.942 Cu. ft

2000 W

1000 W

1500 W

1000 W
5500 W





Oven

Conventional (both
elements)
Top element
Bottom element

Supply voltage (50Hz)











1750 W

750 W

1000 W

230-240 V