Installation, Deciding where to locate your pellet appliance, Removing pellet stove from pallet – Enviro EF2 User Manual
Page 11

Installation
D
ECIDING
W
HERE
TO
L
OCATE
YOUR
P
ELLET
A
PPLIANCE
:
1. Check clearances to combustibles.
2. Do not obtain combustion air from an attic, garage or any unventilated space. Combustion air may
be obtained from a ventilated crawlspace.
3. Do not install the stove in a bedroom.
4. You can vent the stove through an exterior wall behind the unit or connect it to an existing masonry
or metal chimney (must be lined if the chimney is over 6” (15 cm) diameter, or over 28 inches² (180
cm²) cross sectional area). An interior vent can be used with approved pipe passing through the
ceiling and roof.
5. Locate the stove in a large and open room that is centrally located in the house. This will optimize
heat circulation.
6. The power cord is 8 feet (2.43 m) long and may require a grounded extension cord to reach the
nearest electrical outlet.
R
EMOVING
P
ELLET
S
TOVE
F
ROM
P
ALLET
:
To remove your new stove from its pallet, open the left and right side panels. To open the side panels
remove the ash pan cover from the magnets located below the door. Remove the two (2) T-20 screws
located at the bottom corners of the left and right side panels. Remove the two (2) T-20 screws located
between the hopper side rails and the side panels at the front edge of the side panel.
There are two (2) wood screws that are holding the bottom of the stove to the pallet. Remove the screws.
Close the side panels. See “P
EDESTAL
I
NSTALLATION
” to install the pedestal.
Figure 5: Screws to take out to remove stove from pallet.
Fireplace Insert Model
Freestanding
Remove the screw here
11