Clearances to combustibles - freestanding, Clearances to combustibles - fireplace insert, Installation – Enviro EF2 User Manual
Page 13

Installation
C
LEARANCES
TO
C
OMBUSTIBLES
- F
REESTANDING
:
When installing this unit on a combustible floor (for example linoleum, hardwood flooring) a non-
combustible hearth pad must be under the unit. The pad must extend at least the width of the appliance
[22” (558 mm)] and at least the depth of the appliance plus 6” (153 mm) in front of the appliance [29
3⁄4” (756 mm)].
Side wall to unit
- 6 inches
(15 cm)
Back wall to unit
- 1 inches
(2.5 cm)
Corner to unit
- 1 inches
(2.5 cm)
Door front to edge of floor protection
- 6 inches
(15 cm)
30"
(76 cm)
48"
(122 cm)
36"
(91cm)
��
���� ���
��
��� ���
��
��� ���
��
���� ���
���� ����
��
�
�
�
��
�
��
����
���
���
����� ����������
Figure 8: EF2 Freestanding Clearance to Combustibles.
Minimum Alcove width
- 36 inches (91 cm)
Minimum Alcove height
- 48 inches (122 cm)
Minimum Alcove depth
- 30 inches (76 cm)
Figure 9: EF2 Freestanding Minimum Alcove Size.
C
LEARANCES
TO
C
OMBUSTIBLES
- F
IREPLACE
I
NSERT
:
10" (25.4 cm) Mantel
8"
(20.3 cm)
8"
(20.3 cm)
S
id
e
W
al
l
Floor Protection; Minimum 6" (15 cm) in front of door
Figure 10: EF2 Fireplace Insert Clearance to Combustibles.
Refer to Figure 10.
Side wall to unit
- 8 inches
(20.3 cm)
Mantel projection
- 10 inches
(25.4 cm)
Mantel to top of unit - 8 inches
(20.3 cm)
Top facing to unit
- 8 inches
(20.3 cm)
Side facing to unit
- 6 inches
(15.2 cm)
Floor protection
- 6 inches
(15.2 cm)
on either side and to the front must
be protected by non-combustible material.
These dimensions are minimum clearances but it is
recommended that you ensure sufficient room for
servicing, routine cleaning and maintenance.
13