44 Single Tank Conveyor Dishwasher

with

Built In Hot Water Booster WT44

Supply voltage: 534070

208 V/3p/60Hz

534071

208 V/3p/60Hz

534072

240 V/3p/60Hz

534073

240 V/3p/60Hz

Dishwasher has three selectable hot water booster configurations
according to inlet water supply temperature.

Dishwasher requires two separate electrical service connections.
Connection 1 for Hot Water Booster; Connection 2 for running of the
machine (wash pump, tank heat, conveyor drive motor, rinse booster
pump, electronic control). Refer to the information below for Amp
requirements.

Booster 40 °F rise Electrical Characteristics

Hot Water Booster Amp Load Connection 1:

208 V/3p/60Hz

33.35A (12 kW)

240 V/3p/60Hz

28.9A (12 kW)

Wash Pump, Tank heat Amp Load Connection 2:

208 V/3p/60Hz

61.7A (21 kW)

240 V/3p/60Hz

55A (21 kW)

Total Amp Load: 208 V/3p/60Hz

95A (33 kW)

240 V/3p/60Hz

83.9A (33 kW)

Booster 70 °F rise Electrical Characteristics

Hot Water Booster Amp Load Connection 1:

208 V/3p/60Hz

50A (18 kW)

240 V/3p/60Hz

43.3A (18 kW)

Wash Pump, Tank heat Amp Load Connection 2:

208 V/3p/60Hz

61.7A (21 kW)

240 V/3p/60Hz

55A (21 kW)

Total Amp Load: 208 V/3p/60Hz

111.6A (39 kW)

240 V/3p/60Hz

98.3A (39 kW)

Booster 100 °F rise Electrical Characteristics

Hot Water Booster Amp Load Connection 1:

208 V/3p/60Hz

66.6A (24 kW)

240 V/3p/60Hz

57.7A (24 kW)

Wash Pump, Tank heat Amp Load Connection 2:

208 V/3p/60Hz

61.7A (21 kW)

240 V/3p/60Hz

55A (21 kW)

Total Amp Load: 208 V/3p/60Hz

128.3A (45 kW)

240 V/3p/60Hz

112.7A (45 kW)

Inlet Water supply pressure:

22 – 102 psi (150 – 700 kPa)

Inlet Water supply temperature
(booster size can be set on
site
during installation):

140 °F (60 °C)
with booster set as 40 °F rise.
110 °F (44 °C)
with booster set as 70 °F rise.
80 °F (27 °C)
with booster set as 100 °F rise.

Inlet Water supply hardness:

4-8 gpg (7-14 °fH) max

Incoming water line size:

G 3/4

NOTE: Two Hot Water Inlets on machine can be fed by

one incoming Hot Water line.

Drain line size:

G 1-1/2

Water consumption: Gallons/hr: 79.25 gal/hr (300 liters)
Water consumption/rack:

0.4 gal/rack (1.5 l/rack)

Wash Temperature:

160 – 172 °F (71-78 °C)

Wash tank size:

26 gal (100 liters)

Wash pump power:

2 hp (1.5 kW)

Wash pump water flow:

118.9 gal/min (450 l/min)

Rinse Temperature:

180 – 194 °F (82-90 °C)

Rinse pump power:

0.4 hp (0.32 kW)

Rinse pump water flow:

1.32 gal/min (5 l/min)

Hot water booster capacity:

6.2 gal (24 liters)

Initial fill water requirements:

32.2 gal (124 liters)

Productivity racks per hour

200 racks / 3600 dishes

(max speed):

(average 18 dishes per rack)

Productivity racks per hour

130 racks / 2340 dishes

(min speed):

(average 18 dishes per rack)

Table to Table connection:

44

″ (1118 mm)

Number of Tanks:

1

Height with door open:

83-7/16

″ (2119 mm)

Charging hole size (width):

20-7/8

″ (530 mm)

Charging hole size (height):

19-3/4

″ (501 mm)

Net weight:

1012 lb (459 kg)

Shipping weight:

1210 lb (549 kg)

Shipping width:

74-7/16

″ (1890 mm)

Shipping depth:

40-15/16

″ (1040 mm)

Shipping height:

81-1/8

″ (2060 mm)

Shipping volume:

143 cu.ft (4.05 m

3

)

Noise level:

<70 dBA

Unit predisposed to accept external detergent dispensers, detergent
probes and rinse aid dispensers.

Exhaust Requirements

Unit supplied as standard with extended vent hoods
(can be removed during installation if not required).
Exhaust extraction not more than 177 CFM (300 m³/h)
Refer to installation diagram for minimum exhaust hood
installation height .